Operations Manual

Specifications 050 Series 075 Series F75
Motor: Horsepower [kW]
Nonreversing 1/2 [0.373] 3/4 [0.560] Not Applicable
Reversing Fan 1/3 [0.249] 1/3 [0.249] 1 [0.746]
Reversing Cylinder 1/3 [0.249] 1/3 [0.249] 1/3 [0.249]
Gas Models
Gas Connection 1/2 in. NPT 1/2 in. NPT 3/4 in. NPT
Gas Burner Rating:
Btu/hr. [Mj/hr., kW]
130,000 [137, 38.1] Classic Line
165,000 [174,
48.359]
Eco Line
60 Hz 130,000
[137.2, 38.1]
50 Hz 110,000
[116.1, 32.2]
225,000 [237, 65.94]
Electric Models
Heating Element Rating:
Kilowatts
21 kW (240 V/50
Hz)
30 kW (other vol-
tages)
Classic Line - 30 kW
Eco Line - 21 kW
Not Applicable
Steam Models
Steam Connection 3/4 in. NPT 3/4 in. NPT Not Applicable
Steam Coil Rating at 100 psig:
Btu/hr. [kg/hr.]
(recommended operating pressure
80-100 psig)
177,500 [83.14] 210,300 [98.5] Not Applicable
NOTE: All machines are shipped with extra nipple to
convert to metric thread (from Standard).
Specifications and Dimensions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
17 Part No: 70457901ENR14