ELECTRICAL CHARACTERISTICS
Absolute Maximum Ratings
Table 2: Absolute Maximum Ratings
Definition Min Max Unit
VDD_BAT 1.8 3.6 V
Storage Temperature -40 +85 °C
These are stress ratings only. Exposure to stresses beyond these maximum ratings may
cause permanent damage to, or affect the reliability of this module. Avoid using the module
outside the recommended operating conditions defined below. This module is ESD sensitive
and should be handled and/or used in accordance with proper ESD mitigation.
Recommended Operating Conditions
Table 3: Recommended Operating Conditions
Description
Value
Min Typ Max Unit
VDD_BAT 1.8 3.0 3.6 Vdc
Operating Temp.
Range
0 25 70 °C
Regulator Used.
In order to leverage the FCC/IC modular approval, the host system/system integrator must use the
XC6204B302MR (Mfg: Torex: 3.0V fixed regulator SOT23-5 package) regulator.