Administration
Security
3.4.2 Access Control
The CCE access parameter controls TCP access for the CCE (CommsChannel Extender).
This affects the operation of the OpenStage Manager, local CTI access, and HPT access.
When "Disable" is selected, TCP is disabled. With "Enable", there are no restrictions.
With Factory reset claw, the ’hooded claw’ keypad mechanism to initiate a factory reset with-
out requiring an authenticated access can be enabled or disabled.
The Serial port parameter controls access to the serial port. When set to "No password", a ter-
minal connected to the port can interact with the phone’s operating system without restrictions.
When "Passwd reqd" is selected, the serial port requires a password for access (root user is
not available). When "Unavailable" is chosen, the serial port is not accessible.
As a prerequisite, the root user needs to create a user and to define a password via Serial Ac-
cess, so that access can be granted when the Password required prompt is issued.
Administration via WBM
System > Security > Access control
Access control
Submit
Reset
Factory reset claw
CCE access
No Password
Serial port
Enable
;