Specifications
Handset Configuration
Telephony
A31003-M2000-M100-1-76A9, 11/2012
OpenStage WL 3 / WL 3 Plus, Administration Manual 6-29
The following parameters are available under the Numbers and Templates tabs
in PDM and Device Manager:
6.9 Telephony
The following parameters are required for the basic telephony settings.
Parameter name Description Value {default}
Man-down alarm Enable or disable the alarm. Enabled/Disabled
{Disabled}
Man-down detection time Delay before the alarm is activated. 5–255 s {7}
Man-down warning angle The handset tilt from the vertical at
which the alarm is activated.
45, 60 {45}
No-movement alarm Enable or disable the alarm. Enabled/Disabled
{Disabled}
No-movement detection
time
Delay before the alarm is activated. 5–255 s {30}
Warning phase duration Delay before the activated alarm is
sent.
1–255 s {7}
NM-MD extra delay used Enable or disable the possibility of an
extra delay.
Yes/No {No}
NM-MD extra delay time Extra delay before the alarm is sent. 1–20 min {10}
ALS Enable or disable the Acoustic Location
Signal (ALS) after the alarm has been
sent.
Note: The ALS will not be activated if an
automatic call is established after an
alarm has been sent.
Yes/No {No}
Mode for automatic call
after alarm
Off: no automatic call after alarm.
Normal: the call is established as an
ordinary call.
Loudspeaker: the loudspeaker on the
backside of the handset is turned on.
Monitoring: a one-way speech channel
is established, that is, the called part
can only listen to an conversation.
Off, Normal,
Loudspeaker,
Monitoring {Off}
Turn off NM-MD during
call
Enable or disable alarms during a call. Yes/No {No}
Table 5