Specifications
Installation of WLAN Handsets
Installation with Central Device Management (WSG)
A31003-M2000-M100-1-76A9, 11/2012
4-2 OpenStage WL 3 / WL 3 Plus, Administration Manual
4.1.1 Create a Network Template in the WSG
Create one template that contains the network parameters (also include the
security settings). Besides the network parameters, additional parameters might
also be set, for example VoIP settings and IP address to WSG. The template must
be created to prevent the WSG from restoring the parameters to default during
the first synchronization.
NOTE: Only select the parameters that are changed, if all parameters are
selected the system performance decreases.
1. Open a web browser and enter the address to the WSG.
2. Click “Device Manager“. You might be prompted to log on the Device
Manager.
3. Select the Templates tab and click “New“. The New template window is opened.
4. In the Device type and Parameter version drop-down lists, select the
corresponding device type and parameter version to use, respectively.
5. In the Name field, enter a descriptive name of the template.
6. Click “OK“.
7. Set the following network parameters:
• Network settings
1
(located under Network > Network A, B, C, or D)
• VoIP settings
2
(located under VoIP)
• Syslog settings
3
(if any) (located under Device > General)
• WSG settings
4
(located under Device > WSG)
8. Click “OK“ to save the template.
NOTE: : See Working with Templates for tip on how to work with templates when
using both PDM and WSG.
1. All required system settings for the WLAN. For example SSID and Security mode.
2. For example VoIP protocol, Gatekeeper IP address or SIP proxy IP address used to access the
PBX.
3. The parameter “Syslog“ must be enabled in order to set the “Syslog IP address“.
4. IP address and password (if any) to the WSG.