OpenStage M3/M3 Plus OpenStage M3 Ex/M3 Ex Plus on HiPath Cordless Alarm and Emergency Call Configuration Administrator Documentation A31003-M2000-M103-2-A9
Our Quality and Environmental Management Systems are implemented according to the requirements of the ISO9001 and ISO14001 standards and are certified by an external certification company. Copyright © Unify GmbH & Co. KG 07/2014 Hofmannstr. 51, 81379 Munich/Germany All rights reserved. Reference No.
SHB_PNG_TOC.fm For internal use only Contents Contents Tables 0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-3 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 Privacy and data security. . . . . . . . . .
SHB_PNG_TOC.fm Contents For internal use only 6 Structure of the Additional Features menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.1 OpenStage M3/OpenStage M3 Ex . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 OpenStage M3 Plus/OpenStage M3 Ex Plus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2.1 Operating Mode 1: Basic Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2.
SHB_PNG_LOT.fm For internal use only Tables Tables 0 Table 2-1 Table 3-1 Table 3-2 Table 3-3 Table 3-4 Table 3-5 Table 3-6 Table 3-7 Table 3-8 Table 3-9 Table 3-10 Table 3-11 Table 3-12 Table 3-13 Table 3-14 Table 3-15 Table 4-1 Table 4-2 Table 4-3 Table 5-1 Table 6-1 Function overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Parameter – General Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 Parameter – Manual Alarm . . .
SHB_PNG_LOT.fm Tables Table 6-18 Table 6-19 Table 6-20 Table 6-21 Table 6-22 Table 6-23 Table 6-24 Table 6-25 0-4 For internal use only Additional Features - Configuration - Alarm Configuration - Alarms menu. 6-8 Launching the Additional Features - Configuration - PNG Configuration menu 6-9 Launching the Additional Features - Operating Mode menu . . . . . . . . . . . 6-9 Additional Features - Configuration - PNG Configuration menu. . . . . . . . .
SHB_PNG-Einleitung.fm Introduction Overview 1 Introduction Contents This chapter covers the following topics: ● Section 1.1, "Overview" ● Section 1.2, "Privacy and data security" ● Section 1.3, "Notational conventions and symbols used" 1.1 Overview The OpenStage M3 Plus and OpenStage M3 Ex Plus handsets can be used as personal alarm devices with voice communication capability (PNG-S) in Alarm Mode and PNG Mode.
SHB_PNG-Einleitung.fm Introduction Privacy and data security Technical Warning Signal: The handset detects local technical faults or DPS requests. These are signalled to the user. Example: The handset is out of range or the battery charge is too low. The user can subsequently initiate measures in order to resolve the fault. ● A prealarm informs the monitored persons of an impending alarm. The alarm can still be reset during the prealarm time in order to avoid false alarms.
SHB_PNG-Einleitung.fm Introduction Notational conventions and symbols used 1.3 Notational conventions and symbols used This manual uses the following symbols: > 7 "i" identifies useful information. Safety notes Hazard information.
SHB_PNG-Modes.fm Operating modes Mode dependent functions 2 Operating modes The OpenStage M3 Plus and OpenStage M3 Ex Plus handsets can be used as personal alarm devices with voice communication capability (PNG-S). Depending on the available infrastructure and requirements, different ranges of functions can be defined for the OpenStage M3 Plus and OpenStage M3 Ex Plus handsets, which are grouped under the operating modes Basic Mode (BM), Alarm Mode (AM) and PNG Mode (PNG).
SHB_PNG-Modes.
SHB_PNG-Modes.fm Operating modes Alarm Mode: Freely configurable monitoring > 2.3 If a prealarm is signalled during a call, you have to first confirm the prealarm in order to prevent the pending alarm. You can then continue the call. Alarm Mode: Freely configurable monitoring All alarms can be freely configured in Alarm Mode of the OpenStage M3 Plus and OpenStage M3 Ex Plus handsets. Alarm Mode only works in conjunction with an alarm server.
SHB_PNG-Modes.fm Operating modes PNG Mode: Monitoring in compliance with BGR 139 The alarm server acts as the control centre for this personal alarm system (PNA system). The alarm server controls and monitors the PNG-S and responds to its messages and alarms. The CLIP information from the setup message at connection setup is required for managing the PNG-S. The user performs a function test on the sensors prior to activation.
SHB_PNG-Konfig.fm Configuration and activation Overview 3 Configuration and activation In order to be able to configure all of the handset's possible alarm and signalling functions in accordance with your requirements, it is important to understand fundamental relationships and concepts. You should therefore familiarise yourself with the following topics: ● ● For operating mode features, see Chapter 2, "Operating modes".
SHB_PNG-Konfig.fm Configuration and activation Overview Alternatively: 1. Select the Additional Features icon in the main menu. 2. Select [Mode] Activation. > 3.1.2 In monitoring mode: Do not remove the battery pack! Removal of the battery pack will result in a technical alarm being triggered in the HNA. Configuration You can configure all operating mode parameters in this menu independently of one another as well as define emergency call numbers and change the service PIN.
SHB_PNG-Konfig.fm Configuration and activation Overview Procedure: 1. Select the Additional Features icon in the main menu. 2. Select Operating Mode. 3. Enter the five-position service PIN and confirm with OK. 4. Select one of the three operating modes and confirm with Selection. 3.1.4 Display Rotate (OpenStage M3 Plus and OpenStage M3 Ex Plus only) Use this menu option to activate and deactivate the automatic position-dependent rotation of the information on the display.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu 3.2 Configuration menu The alarming signal parameters that define the alarm response are defined under the Configuration menu option. Configuration can be performed here for each operating mode, independently of the other operating modes. The parameters are described independently of the operating mode. If a parameter is not available in an operating mode, this is noted in the parameter description.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu 3. Enter the five-position service PIN and confirm with OK. 4. Select one of the three operating modes. 5. Select Alarms. 6. Select General Settings. 7. Change the values of the following parameters: Parameters Control Port Basic Alarm Destination Alarm Destination 1 Alarm Destination 2 Alarm Destination 3 Alarm Call Count Autom. Alarm Calling Time Audio Channel Table 3-1 8.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Manual Alarm You can configure all settings here for the manual alarm, in other words for the alarm triggered with the red alarm key. > The red key is assigned for the manual alarm in Alarm Mode and PNG Mode following activation. The numbers configured under the emergency call (Section 3.2.2, "Emergency Call") are selected if no mode is active.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Wide-ranging solutions are feasible using different configuration options.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Parameters Operating Mode Value Range Standard Value Activation BM/AM/PNG On/off On BM/AM 10 ... 900 s 90 s PNG 10 ... 90 s 90 s BM/AM 0 ... 300 s 15 s PNG 0 ... 30 s 15 s BM -1 112 AM/PNG (up to 32 digits) (blank) Response Time Prealarm Time Alarm Destination Table 3-4 1 8.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Parameters Response Time Prealarm Time Alarm Destination Table 3-5 1 Operating Mode Value Range Standard Value BM/AM 10 ... 900 s 90 s PNG 10 ... 90 s 90 s BM/AM 0 ... 300 s 15 s PNG 0 ... 30 s 15 s BM -1 112 AM/PNG (up to 32 digits) (blank) Parameter – Man Down Alarm The alarm destination is the same in Basic Mode of the M3 Plus for all alarms and is entered under "General Settings". 8. Confirm with Save.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Parameters Alarm Destination Table 3-6 1 8. Operating Mode Value Range Standard Value BM -1 112 AM/PNG (up to 32 digits) (blank) Parameter – Time Alarm The alarm destination is the same in Basic Mode of the M3 Plus for all alarms and is entered under "General Settings". Confirm with Save. Escape Alarm The Escape Alarm can be activated optionally.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu 8. Confirm with Save. Pull Cord Alarm The Pull Cord Alarm can be activated optionally. It is triggered if the pull cord contact (cord) is not detected over a defined configurable period of time, i.e. has been removed. For more information on alarm destinations please refer to Chapter 4, "Control ports and alarm destinations". Procedure: 1. Select the Additional Features icon in the main menu. 2. Select Configuration. 3.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu 1. Select the Additional Features icon in the main menu. 2. Select Configuration. 3. Enter the five-position service PIN and confirm with OK. 4. Select one of the three operating modes. 5. Select Alarms. 6. Select Alarm Signal. 7. Select Prealarm or Alarming Signal. 8.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu 6. Change the values of the following parameters: Parameters Operating Mode Value Range Standard Value Automatic BM/AM/PNG On/off Off Manual BM/AM/PNG On/off On Table 3-10 7. Parameter – [Mode] Activation Confirm with Save. 3.2.1.3 Control Ports The control ports are phone numbers of the alarm server that are used for signalling the states/ events between the handset and the alarm server.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Control Ports in Basic Mode: Parameters Sample Value Value Activ.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Furthermore, the handset checks whether the battery is sufficiently charged. If the battery is not adequately charged, a technical fault is likewise reported. No settings can be made here. Procedure: 1. Select the Additional Features icon in the main menu. 2. Select Configuration. 3. Enter the five-position service PIN and confirm with OK. 4. Select one of the three operating modes. 5. Select Techn. Warning. 6.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu 6. Keep the handset still in a vertical position and confirm with OK. 7. Shake the handset vigorously until the test is successful. 8. Keep the handset still in a vertical position until the test is successful. 9. Press the red alarm key at the top of the handset. 10. Remove the connector with the pull cord from the socket at the lower end of the handset and insert it again. > the manufacturer.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Procedure: 1. Select the Additional Features icon in the main menu. 2. Select Configuration. 3. Enter the five-position service PIN and confirm with OK. 4. Select one of the three operating modes. 5. Select Alarm Signal PIN. 6. Change the values of the following parameters: Parameters Value Range Standard Value PIN On/off On Please enter the alarm signal PIN (5 digits) 11111 Table 3-14 7.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu > Note: – Make sure that the alarm destination is always accessible if possible. – The possibility that the alarm destination cannot be reached cannot be excluded. – Make sure that the alerting party is recognised by the alarm destination. Transmission of the caller's number is necessary, for example, in order to identify the alerting party. – Alarm calls can incur costs.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu Parameters Value Range Standard Value Emergency Nr. 2 (up to 32 digits) (blank) Emergency Nr. 3 (up to 32 digits) (blank) Calling Time 0 ... 60 s 30 s Audio Channel Handset / Handsfree Handset mode Emergency Key SP On/off On Emergency Key LP On/off On Emerg. Key Locked On/off Off Emergency Signal SP On/off On Emergency Signal LP On/off Off Melodies Alarm 1 ... 5 Alarm 1 Volume 1 ... 5 3 Table 3-15 7.
SHB_PNG-Konfig.fm Configuration and activation Configuration menu 1. Select the Additional Features icon in the main menu. 2. Select Configuration. 3. Enter the five-position service PIN and confirm with OK. 4. Select Service PIN. 5. Enter an individual five-position PIN, repeat the input and confirm with OK. 7 Make sure to note down the newly set PIN. If you forget the PIN, it can only be reset by your service partner for a fee by resetting the handset.
SHB_PNG-Konfig.fm Configuration and activation Exporting and transmitting the configuration 3.3 Exporting and transmitting the configuration The Firmware Update Tool can be used to export the configuration from devices in the M3 family and transfer it to other devices. > The tool is available on the SWS.
SHB_PNG-Ports.fm Control ports and alarm destinations Syntax of the control ports and alarm destinations 4 Control ports and alarm destinations Control ports and alarm destinations are phone numbers used for communication between an alarm server and the handset. Control ports are the phone numbers used for calls from the alarm server to control the handset while alarm destinations are called by the handset in order to report alarms and statuses to the alarm server. Only three control ports, i.e. Activ.
SHB_PNG-Ports.fm Control ports and alarm destinations Example Parameters Phone number syntax Pull Cord Alarm QUERKZ + NWKZ + 0 + 6 Emergency Nr. 1 QUERKZ + NWKZ + 0 + 7 Manual Alarm LP QUERKZ + NWKZ + 0 + 8 Table 4-1 4.1.
SHB_PNG-Ports.
SHB_PNG-Check.fm Response times under VDE 0825 5 Response times under VDE 0825 The response times listed in this table must be observed in accordance with BGR 139.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3/OpenStage M3 Ex 6 Structure of the Additional Features menu 6.1 OpenStage M3/OpenStage M3 Ex Additional Features Service PIN Configuration Basic Configuration BM Activation Please enter Basic Mode BM Activation Configuration Service PIN: Emergency Call Control Ports [00000] Service PIN Techn.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3/OpenStage M3 Ex Emergency Call Service PIN 30 sec. (0-60 sec.) Audio Channel: ----- Handsfr./Handset Emergency Key: Shortpress On Off Longpress On Off Emerg. Key Locked: On Off Emergency Sig.: Shortpress On Off Longpress On Off Melodies: Alarm1 (15) Volume 3 (1-5) Table 6-3 Additional Features - Configuration menu General Settings Non Movement Alarm Man Down Alarm Time Alarm Autom.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus 6.2 OpenStage M3 Plus/OpenStage M3 Ex Plus 6.2.1 Operating Mode 1: Basic Mode Additional Features Service PIN Configuration Basic Configuration BM Activation Please enter 1. Basic Mode Alarms Configuration Service PIN: 2. Alarm Mode BM Activation Operating Mode [00000] 3. PNG Mode Control Ports Emergency Call Techn.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus Alarms BM Activation Control Ports Techn. Warning Volume 3 (1-5) Table 6-7 Additional Features - Configuration - Basic Configuration menu Adjust Sensor Reset to default Please adjust Reset Base Settings handset in to vertical position default? Back No OK Table 6-8 Yes Additional Features - Configuration - Basic Configuration menu Emergency Call Service PIN Emergency Nr.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus General Settings Non Movement Alarm Man Down Alarm Time Alarm Autom. Alarm: Activation: Activation: Activation: On Off On Off On Off On Off Off in Response Time: Response Time: Response Time: Charger 90sec. (10-900 sec.) 90sec. (10-900 sec.) 15 min. (1-120 min.) Alarm Destinat. 1: Prealarm: Prealarm: Prealarm: 112 15sec. (0-300 sec.) 15sec. (0-300 sec.) 15sec. (0-300 sec.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus 6.2.2 Operating Mode 2: Alarm Mode Additional Features Service PIN Configuration Alarm Configuration BM Activation Please enter 1. Basic Mode Alarms Configuration Service PIN: 2. Alarm Mode AM Activation Operating Mode [00000] 3. PNG Mode Control Ports Emergency Call Techn.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus Alarms AM Activation Control Ports Techn. Warning Sig. Num.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus Emergency Call Service PIN Volume 3 (1-5) Table 6-16 Additional Features - Configuration menu General Settings Manual Alarm Non Movement Alarm Man Down Alarm Control Port Basic: Alarm Key: Activation: Activation: -------- Shortpress On Off On Off On Off Alarm Destination: Longpress On Off Response Time: Response Time: -------- Alarm Key locked: 90sec. (10-900 sec.) 90sec. (10-900 sec.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus Time Alarm Escape Alarm Pull Cord Alarm Alarm Signal Alarm 1 (1-5) Volume 5 (1-5) Table 6-18 6.2.3 Additional Features - Configuration - Alarm Configuration - Alarms menu Operating Mode 3: PNG Mode Additional Features Service PIN Configuration PNG Configuration PNG Activation Please enter 1. Basic Mode Alarms Configuration Service PIN: 2.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus Alarms PNG Activation Control Ports Techn. Warning Pull Cord Alarm Alarm Recall-loud: Warning signal: Alarm Signal Sig. Num.: -------- On Off Alarm Recall-quiet: Melodies : Sig. Num.: -------- Alarm 3 (1-5) Alarm Recall-disc: Volume 3 (1-5) Sig. Num.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus Emergency Call Service PIN Emergency Sig.
SHB_PNG-Menu.fm Structure of the Additional Features menu OpenStage M3 Plus/OpenStage M3 Ex Plus Time Alarm Escape Alarm Pull Cord Alarm Alarm Signal 15sec. (0-15 sec.) 15sec. (0-15 sec.) 15sec. (0-15 sec.
SHB_PNG_abb.fm Abbreviations For internal use only Abbreviations Y The following list explains the abbreviations used in this manual.
SHB_PNG_IX.