User's Guide

April 4, 2019
USER GUIDE: UBS-200L LF DESKTOP READER
45
Appendix 1 Default Settings and Response/Error Codes | Unified Information Devices
001.006.03 v1.3
Reserved LF Module Settings
The following settings are programmed at the factory to ensure proper operation, and should not be
changed by the user. The factory default settings are listed below. In case a parameter is inadvertently
changed, it can be restored using the values in the table. Contact UI Devices for assistance in restoring
default settings.
Parameter
Default Value
BD
3
EC
0
HF
1
FD
2
SA
0
TI
225
TO
130
TP
172
TS
1
TT
0
TZ
110
DSN
xxxxxx
PWC
1
Default Host Serial Port Settings
Common Response/Error Codes
Response/Error Code
Meaning
<NAK>#00<CR>
Unknown Command
<NAK>#02<CR>
Incorrect Parameter
<NAK>#09<CR>
Read Error
<NAK>#10<CR>
Antenna Failure
XXXXXXXX<CR>
No Transponder