Specifications
OM-HY/6G(CE) 7
The HY-6G(CE) steamer is suitable for installation in combustible and noncombustible
locations. Minimum clearances for installation are:
Right Side 300 mm (12 inches)
Left Side 0 mm (0 inches)
Rear of Flue 150 mm (6 inches)
However, for easy service at least 300 mm (12 inches) clearance is required for the
right side of the unit, and it may not be installed within 300 mm (12 inches) of a heat
source, as stated in the Caution above.
The unit must be installed in a well-ventilated room with an adequate air supply. The
steamer must be installed beneath a ventilation hood, since gas combustion products
exit the appliance.
Any item which might obstruct or restrict the flow of air for combustion and ventilation
must be removed. Do not obstruct the flue cover or any front, side, rear, or top vents
after installation.
The area directly around the appliance must be cleared of all combustible material.
The installation must conform with local codes or, in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1, latest edition, including the following:
The unit and its individual shutoff valve must be disconnected from the gas supply
system during any pressure testing of that system at test pressures in excess of ½
PSI (3.45 kPa). It must be isolated from the gas supply piping system by closing its
individual manual shutoff valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than ½ PSI (3.45 kPa).
1. Electrical Supply Connection
The unit is designed for connection to fixed wiring. A suitably rated isolating
switch with contact separation of at least 3 mm on both poles must be fitted
to the installation. Wiring must be executed in accordance with the regulations
listed on page 2 of this manual.
Cable entry is at the bottom rear right side of the appliance. To gain access the
panel must be removed. Open the lower front panel by removing its screws. Lift
the panel and swing its bottom toward you. Set the panel aside.
Provide 230 Volt, 50 Hz, Single Phase, 15 Ampere service. Maximum load is 2½
amps. The electrical schematic is located in the service compartment. A copy is
also printed at the rear of this manual.
2. Gas Supply Connection
Incoming service must be of sufficient size to supply full rate without excessive
pressure drop. A gas meter is connected to the service pipe by the Gas Supplier.
Any existing meter should be checked out by the Gas Supplier to ensure that
it has adequate capacity to provide the required rate of gas to the steamer, in
addition to any other equipment.
WARNING
THE UNIT MUST BE INSTALLED BY
PERSONNEL WHO ARE QUALIFIED TO
WORK WITH ELECTRICITY AND PLUMBING.
IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE
TO THE EQUIPMENT. THE UNIT MUST
BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES.
CAUTION
DO NOT INSTALL THE UNIT WITH THE
RIGHT SIDE VENTS BLOCKED OR WITHIN
30 CENTIMETERS OF A HEAT SOURCE
(SUCH AS A BRAISING PAN, DEEP FRYER,
CHAR BROILER, OR KETTLE). TO AVOID
DRAINAGE PROBLEMS, LEVEL THE UNIT
FRONT TO BACK, OR PITCH IT SLIGHTLY
TO THE REAR.
Installation
CAUTION
THE UNIT MUST HAVE A SEPARATE
EARTHING WIRE FOR SAFE OPERATION.
MODEL
WIDTH
mm (in)
DEPTH
mm (in)
HEIGHT
mm (in)
WEIGHT
Kg (lbs)
HY-6G(CE) 549 (21.6) 894 (35.2) 1464 (57.6) 193 (425)