Specifications
OM-HY/6G(CE) 33
7. Using a wrench, remove the two top and one bottom bolts which hold the manifold to the steam generator manifold
mounting bracket.
8. Remove the screws in the heat shield.
9. Remove the burner manifold from the appliance.
10. Remove the flame retention springs and injectors as required.
To Reassemble:
11. Replace the injectors and retention springs. Ensure a suitable gas sealant is used on the threads of the injectors to ensure
a gas tight seal.
12. Fit the burner manifold to the steam generator manifold mounting bracket.
13. Reinstall and tighten the aluminum tubes to the burner manifold.
NOTE: Ensure all gas connections are sound before continuing.
Q. Timer Assembly (P/N 100983) & Timer Fastener Nut (P/N 101145)
1. Remove the three hex nuts which retain the control panel cover. Remove the cover.
2. Remove the knob from the timer. Under the knob is a hexagonal nut which holds the time mechanism to the steamer. Note
that there is a flat on the timer shaft which corresponds to a frictional mounting hole on the knob.
3. From the left side, unplug the five terminals/wires (violet, gray, black, tan and white) from the timer mechanism and
unplug the two black timer motor leads.
4. With an open-ended wrench, remove the hex nut holding the timer in place. The timer may then be removed from inside
the compartment.
NOTE: Right below the timer shaft, the timer has a small plastic disk molded onto the case. There is a corresponding hole
punched into the front panel. This hole may be seen from the inside of the compartment only when the timer is removed.
To Install:
5. Fit the timer in place making sure that it is properly placed so that the disk on the timer fits into the punched hole in the
front panel.
6. Once the timer is properly located, tighten the hex nut so that the timer does not slip or rotate. Do not over-tighten the nut.
7. Align the flat of the knob hole with the flat on the timer shaft. Press the knob firmly onto the timer shaft.
8. Plug in the wires identified above and connect the two black wires from the motor leads.
9. Reattach the control panel cover.
R. Fan (P/N 096790)
IMPORTANT: Make sure that the fan has come to a complete stop before attempting any work on the fan.
1. To remove the fan from either the top or bottom cavity, open the door and remove the pan support wire rack in front of the
fan.
2. With an allen wrench, loosen the set screw which holds the fan to the motor shaft.
Service Procedures