Operating instructions

OM-HY-6E
13
2. Steam Generator and Cooking Chamber
Regular deliming, depending on your steamer usage
and local water quality, must be done to enhance
performance and prolong the life of your
HyPerSteam™ convection steamer. Steamer must
be turned off after every use to prevent lime scale
buildup - do not run steamer continuously.
ALWAYS USE HOT PADS OR MITTS WHEN 
HANDLING HOT STEAMER PANELS OR RACKS.
RECOMMENDED TOOLS & CLEANERS
:
- Groen Delimer/Descaler (Part Number 114800). Do
NOT use any product containing chlorides or
sulfamic acid, including hydrochloric acid .
- Nylon scrub pad, cloth and/or sponge
DELIMING STEPS HY-6E (Use Touch Pad):
1. Press ON/OFF to turn off. Open door(s).
2. Let cavity cool for 5 minutes or longer. While
cool, wipe out cavity. Drain holes at rear of
cavity must be clear of debris. Close door(s).
3. Press and hold CLEAN while turning steamer on
pressing ON/OFF, until only DELIME and 
POWER light remain on (all lights will turn on,
then off, except DELIME and POWER.
4. After 5 minutes, beeper will beep rapidly,
signaling you to add Groen Delimer/Descaler. 
Door(s) must remain closed for entire delime
cycle.
5. Pour 1 pint (2 cups) of delimer per cavity into
upper and/or lower delimer ports(s). Press
CLEAN. Double -stacked unit cavities may be
delimed together or separately.
6. Delime cycle will start, taking about 30 minutes. 
When delime cycle is complete, DELIME light
will appear, DONE light will flash and beeper will
beep.
7. Press ON/OFF to turn steamer off. Let cavity 
cool for 5 minutes or longer. Open door(s), 
wipe out inside of cavity and wipe door 
gasket.
8.  To use steamer, press ON/OFF. When READY 
 light appears, steamer is ready to use.
NOTES:
- If delime light flashes rapidly (5 times per second),
press DELIME to restart delime cycle.
- If power outage occurs during deliming, delime
cycle must be restarted. Press DELIME.
- For best performance, do not interrupt delime cycle. 
If delime cycle must be stopped, press ON/OFF to
turn off. Let cavity cool for 5 minutes or longer. 
Press ON/OFF to turn on. Set timer for 5 minutes. 
After beeper beeps, press ON/OFF to turn off. Let
cavity cool for 5 minutes or longer, carefully open
door(s) and wipe out cavity completely.
Deliming
Port
13
om-HY-6e