Datasheet

4
S P E C I F I C A T I O N S
Wiring Gauge Requirements (AWG)*
Total Length to Device
Output Load Current @ 12VDC
100mA 250mA 500mA 1A
6.1 m (20 ft) 22 22 22 18
15.2 m (50 ft) 22 22 22 18
30.5 m (100 ft) 22 22 18 18
* Use CTE cable connectors that comply with local electrical codes.
Default I/O State Matrix: Lock
Dry
NO COM NC
Door Locked
Initial State
Opened Shorted Shorted
Unlocked
REN, REX, or REL is shorted; or
the reader has granted access
Shorted Shorted Opened
Powered
NO COM NC
Door Locked
Initial State
0V GND +12V
Unlocked
REN, REX, or REL is shorted; or
the reader has granted access
+12V GND 0V
Default I/O State Matrix: Aux
Dry
1
NO COM NC
Door Locked
Initial State
Opened Shorted Shorted
Unlocked
REN, REX, or REL is shorted; or
the reader has granted access
Shorted Shorted Opened
Powered
2
NO COM NC
Door Locked
Initial State
+12V GND 0V
Unlocked
REN, REX, or REL is shorted; or
the reader has granted access
0V GND +12V
1
Example 1: Recommended Setup - Connect AUX DRY to automatic door opener
with external power.
2
Example 2: Recommended Setup - Connect AUX POWERED to siren (12V / 0.33A /
4W) for door position warning.