Owner`s manual

12
< Band Plan 3>
These Frequency Ranges suit to initial step setting. Step setting will change
them.
These Modulations are initial settings. They can be selected from AM / FM /
NFM / WFM / FMB / AUTO.
These Steps are initial settings.
Steps can be selected from 5 / 6.25 / 8.33 / 10 / 12.5 / 15 / 20 / 25 / 50 / 100 /
AUTO (kHz).
If “AUTO” is selected for Modulation or Step, the scanner works with the
modulation or step of this table.
If the Step is set to 15 kHz, inputable frequencies are xxx.x000, xxx.x150,
xxx.x300, xxx.x450, xxx.x600, xxx.x750, and xxx.x900. For example, the next
frequency of 400.0900 MHz is 400.1000 MHz.
If the Step is set to 8.33kHz, inputable frequencies are xxx.x000, xxx.x083,
xxx.x166, xxx.x250, xxx.x333, xxx.x416, xxx.x500, xxx.x583, xxx.x666,
xxx.x750, xxx.x833, and xxx.x916.
For example, the next frequency of 100.0916 MHz is 100.1000 MHz.
Frequency (MHz)
Modulation Step (kHz) Remark
Lower Edge Upper Edge
25.0000 29.9950 FM 5
30.0000 79.9937 FM 6.25
80.0000 82.9937 FM 6.25
83.0000 87.2937 FM 6.25
87.3000 107.9500 FMB 50
108.0000
108.0000
136.9875
136.9916
AM
12.5
/ 8.33
AIR BAND
137.0000 137.9950 FM 5
138.0000 157.9937 FM 6.25
158.0000 160.5937 FM 6.25
160.6000 162.5937 FM 6.25
162.6000 173.9937 FM 6.25
174.0000 215.9500 WFM 50
216.0000 224.9950 FM 5
225.0000 399.9750 AM 25
400.0000 405.9875 FM 12.5
406.0000 439.9937 FM 6.25
440.0000 465.9937 FM 6.25
466.0000 469.9937 FM 6.25
470.0000 512.0000 FM 6.25
806.0000 960.0000 FM 12.5
1240.0000 1300.0000 FM 12.5
UB356ZH.fm Page 12 Wednesday, December 19, 2007 11:28 AM