Specifications
D
PK-232 MBX OPERATING MANUAL COMMAND LIST
COMMAND MNEMONIC FUNCTION
RWWhdlc OFF Starts Raw HDLC mode
RBaud 45 bauds (60 WPM) Sets the Baudot RTTY baud rate selection
Rcve Im
mediate Command Selects the receive mode Morse/RTTY/AMTOR
RECeive $04 <CTRL-D> Selects the Receive character used in text
REDispla $12 <CTRL-R> Re-displays current terminal input buffer
RELink OFF Re-connects
after link fails due to retries
RESET Immediate Command RESETs PK-232 and bbRAM to factory defaults
RESptime 0 Sets the minimum delay before sending an ACK
RESTART Immediate Command Restarts PK-232, same as
turning power off/
on
REtry 10 Sets the maximum number of packet repeats
RFec ONReceives FEC in AMTOR Standby
RFRame OFF Checks RTTY characters for framing errors
RXRev OFF Reverses the received data mark-space sense
SAmple Immediate Command Enters the raw data sampling mode
SELfec Imm
ediate Command Starts a selective FEC call with SELCAL
SEndpac $OD <CTRL-M> Sets the converse mode "Send packet" char.
Slgnal Immediate Command Starts the Signal Identification mode
SLottime 30 Sets the P-persistent CSMA slot time
SQuelch OFF Sets the receiver squelch carrier polarity
SRXall OFF Allows reception of ALL received SELFEC calls
STart $11 <CTRL-Q> Sets character to start sending terminal data
STOp $13 <C
TRL-S> Sets character to stop sendina terminal data
TBaud 1200 bauds Sets the ASCII terminal d
ata rate
TClear Immediate Command Clears the transmit Buffer (Non-packet modes)
TDBaud 96 Sets the receive data rate for TDM signals
TDChan 0 Sets the receive channel for TDM signals
TDm Immediate Command Enters the TDM receive mode
TIme S14 <CTRL-T> Inserts the time (in DAYTIME) in text
TMail OFF Enables AMTOR and Pactor Maildrop
TMPrompt (see text) Sets an 80 character AMTOR Maildrop Message
TRACe OFF Enables a Hex dump of received data
Trans Immediate Command Enters the Transparent data mode
TRFlow OFF Enables software flow control RX in Trans.
TRIes 0 (zero). Displays or forces packet retry counter
TXDelay 30 Sets the PTT key-to-data delay (X10 ris)
TXFlow OFF Enables software flow control TX in Trans.
TXrev OFF Reverses transmitted mark-space data sense
UBit 0 Controls seldom used ON/OFF commands
UCmd 0 Controls seldom used numeric commands
Unproto CQSets the UI packet frame sending Path/address
USers 1 Sets allowed number of packet multi-connects
USOs OFF Sets RTTY 'unshift on space’
VHF ONSelects VHF Packet - wide (1000 Hz) shift
WHYnot OFF Displays reason wh
y packet not displaye
d
WIdeshft OFF Selects RTTY- wide or narrow (200 Hz) shift
Wordout OFF Sets Word output in RTTY/AMTOR/Pactor modes
WRu OFF Enables auto-answerback (AAB) in RTTY/ASCII
XBaud 0 Sets 8530 baud rate to receive Baudot/ASCII
XFlow ONSets Software (XON/XOFF) RS-232 flow control
Xmit Immediate Command Starts sending Baudot/Morse/FAX transmission
XMITOk ONAllows transmitter PTT line to be keyed
XOff $13 <CTRL-S> Sets character to stop sending received data
XON $11 <CTRL-Q> Sets character to start sending received data
ZFree Immediate Command Returns number of blocks of available memory
ZStatus Immediate Command Returns status of several internal parameters
4