Specifications

D
PK-232 MBX OPERATING MANUAL COMMAND LIST
COMMAND DEFAULT FUNCTION
MDCheck Immediate Command Allows you to check into your own MailDrop
MDigi OFF Monitors packet frames that you dig
ipeat
MDMon OFF Monitors stations using your MailDrop
MDPrompt (see text) Sets an 80 character MailDrop message prompt
MFIlter $80 Filters received ASCII characters
MFrom ALL (calls) Monitors packets FROM other packet stations
MHeard Immediate Command Displays call packet signs heard
MId 0 Enables a Morse ID to be sent in packet
MMsg OFF Enables the MailDrop sign on message
Monitor 4 (UA DM C D I UI) Sets the packet Monitor
mode level (0-6)
MOrse Immediate Command Starts the Morse mode, unlo
ck speed
MProto OFF Enables monitoring of all packet protocols
MRpt ON Shows digipeaters in packet
headers
MSPeed 20 Sets the Morse speed in WPM (5-99)
MStamp OFF Time-stamps monitored packet frames
MTExt (see text) Sets a 120 character MailDrop sign-on message
MTo Empty; enter calls Monitors packets TO other station callsigns
MWeight 10 Sets the Morse transmit dot
weighting
MXmit OFF Monitors transmitted packet frames
MYAlias None; enter yours Sets the alternate MYCALL for digipeating
MYALTcal Empty; enter yours Sets the alternate AMTOR SELCAL
MYCall PK232; enter yours Sets YOUR packet call sign (MUST BE ENTERED)
MYIdent None; enter yours Sets your CCIR-625 7-character AMTOR SELCAL
MYMail None; enter yours Sets your Packet MailDrop callsign
MYPTcall None; enter yours Sets your Pactor callsign
MYSelcal Empty; enter yours Sets your AMTOR SELCAL, 4 letters
NAVMsg ALL Determines which NAVTEX messages you monitor
NAVStn ALL Determines which NAVTEX stations
you monitor
NAvtex I
mmediate Command Starts the NAVTEX/AMTEX receive mode
NEwmode ON Returns to Command mode at disconnect
NOmode OFF Sets NO mode changes (eg. cmd: to CONVERSE)
NUCr OFF Sends Nulls to
terminal after <CR>
NULf OFF Sends Nulls to terminal after <LF>
NULLs 0 (zero) Sets the number of for NUCR and NULF
Nums Immediate Command Forces FIGS case in Baudot, AMTOR and TDM
OK Immediate Command Transfers to mode after Signal Identification
Opmode Immediate Command Displays current PK-232 operating mode
PAcket Immediate Command Starts the Packet Mode
PACLen 128 Sets the number user data bytes in a packet
PACTime AFTER 10 Sets the packet automatic transmit timer
PACTor Immediate Command Enters the Pactor
mode (PT for short)
PARity 3 (even) Sets the terminal vrogram pari
ty
(0-3)
PASs $16 <CTRL-V> Sets the converse mode pass character
PASSAll OFF Ignores CRC in receiving packets (Junk mode)
PErsist 63 Sets the P-persistent CSMA threshold
PPersist 014 Selects P-persistent CSMA operation
PRCon OFF Enables a para
llel printer you have connected
PPFax ON Prints received PAX to parallel printer
PRout OFF Sends all received data to parallel printer
PRType 2 (Epson) Sets the graphics emulation for FAX printing
PT200 ON Allows 200 bauds for Pactor if link is good
PTConn Immediate Command Starts a Pactor connect with (CALLSIGN)
PTHuff 0 Selects Pactor data compression (0 = OFF)
P
TList Immediate Command Starts the Pactor Listen mode
PTOver $1A <CTRL-Z> Sets the Pactor link direction change char.
PTSend Immediate Command Starts the Pactor unproto send mode (call CQ)
3
From The N3UJJ.COM Document LibraryFrom The N3UJJ.COM Document Library