Specifications

PK-232 OPERATING MANUAL COMMAND SUMMARY
PTSend – “n, x” Default: 1,2
Mode: Pactor Host: PD
Parameters:
”n” - 1 or 2 selects the transmit baud rate.
- 1 to 5 selects the number of times the data is repeated.
PTS “n, x” initiates an unproto Pactor transmission. To end the transmission,
type <ctrl-D>.
“n”
1 selects 100 baud,
2 selects 200 baud.
In order to increase the probability of correct transmission, the unproto
Pactor transmission sends the message data a selected number of times.
The parameter x sets the number of times the data is sent.
Example:
PTS 1 3 <Enter> would start a 100 baud unproto transmission with the
message data sent three times.
The transmission may be started using the default, 100 baud, two repeats, by
typing "PTS" without “n x.”
Example:
PTS <Enter>
2/93 A-65c