SDS
SAFETY DATA SHEET S19040202001001
Page 6 of 16 Version Number: V2.0
handling
contact with skin, eyes or clothing. Ensure adequate ventilation. Do not
breathe dust/fume/gas/mist/vapors/spray.
Conditions for safe
storage, including any
incompatibilities
Storage: Keep containers tightly closed in a dry, cool and well-ventilated
place.
Incompatible Products: Strong acids. Strong oxidizing agents. Strong
bases.
Section 8 – Exposure Controls and Personal Protection
Control parameters
Exposure Guidelines
Chemical Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Copper
7440-50-8
TWA: 0.2 mg/m³ fume
TWA: 1 mg/m³ Cu dust
and mist
TWA: 0.1 mg/m³ fume
TWA: 1 mg/m³ dust and
mist
(vacated) TWA: 0.1
mg/m³ Cu dust, fume,
mist
IDLH: 100 mg/m³ dust,
fume and mist
TWA: 1 mg/m³ dust
and mist
TWA: 0.1 mg/m³ fume
Aluminum foil
7429-90-5
TWA: 1 mg/m³
respirable fraction
TWA: 15 mg/m³ total
dust
TWA: 5 mg/m³
respirable fraction
(vacated) TWA: 15
mg/m³ total dust
(vacated) TWA: 5 mg/m³
respirable fraction
(vacated) TWA: 5 mg/m³
Aluminum
TWA: 10 mg/m³ total
dust
TWA: 5 mg/m³
respirable dust
Lithium Cobalt Oxide
12190-79-3
TWA: 0.02 mg/m³
-
-
Nickel
7440-02-0
TWA: 1.5 mg/m³
TWA: 1 mg/m³ (vacated)
TWA: 1 mg/m³
IDLH: 10 mg/m³
TWA: 0.015 mg/m³
Lithium manganese
oxide
12057-17-9
TWA: 0.2 mg/m³ Mn
(vacated) Ceiling: 5
mg/m³
Ceiling: 5 mg/m³ Mn
IDLH: 500 mg/m³ Mn
TWA: 1 mg/m³ Mn
STEL: 3 mg/m³ Mn
*ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value
OSHA PEL: Occupational Safety and Health Administration - Permissible Exposure Limits NIOSH
IDLH Immediately Dangerous to Life or Health
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992) See section 15 for national exposure control parameters
Appropriate engineering
Engineering Measures: