Specifications

Vancouver Police Service
Command
Production Specification
SVI #847 Page 72 of 107 September 18, 2012
CURBSIDE INTERIOR AREA (IC4)
ADDITIONAL SOUND INSULATION
In additional to the insulation as specified, the interior area shall include additional sound deadening insulation between
the interior walls to isolate the interior area from the balance of the apparatus.
WALL MOUNTED PHONE
There shall be one (1) Vancouver Police Department supplied phone(s) mounted on the rear face of the sliding pocket
door stub wall. The phone system shall be programmed by the Vancouver Police Department to allow the extension to
operate as an intercom between the Command and Negotiator area.
INTERIOR DESK
The interior of apparatus shall be provided with a desk top which shall be 24" deep and located approximately 30" from
floor. The front edge of the desk top shall be reinforced with 2" x 2" tubing in order to support a person sitting on the edge
of the desk.
The desk top surface shall be fabricated of 3/16" smooth finish aluminum. It shall have a 2" vertical downward edge along
front to cover the 2" x 2" reinforcement. There shall be 2-1/2" diameter holes with plastic edge grommet provided at each
rear corner for wiring of future equipment located on the desk top. The desk top shall be painted dark gray with a hammer
tone powder coat paint finish for a hard and durable surface.
WALL MOUNTED CONNECTION PANEL
There shall be two (2) wall mounted connection panel(s) provided in the interior. Panel(s) shall be constructed of 1/8"
smooth finish aluminum and painted with a hammer tone powder coat paint finish for a hard durable surface. Paint color
shall be gray or black.
Unless otherwise noted, each panel shall contain the following items:
There shall be two (2) phone connection(s) with wall plate provided in the front face of the connection panel.
There shall be two (2) data port(s) provided in the front face of the component console. The cabling shall terminate at the
equipment rack mount patch panel with 12" of slack per cable. A cable certification report confirming that all network
wiring complies with CAT6 specifications shall be included with the completed apparatus.
There shall be one (1) two-gang 12 VDC outlet(s) provided in the front face of the component console.
There shall be one (1) 120 VAC, 20 amp, duplex straight-blade receptacle (NEMA 5-20R) outlet(s) provided in the front
face of the component console.