Specifications
Vancouver Police Service
Command
Production Specification
SVI #847 Page 68 of 107 September 18, 2012
CURBSIDE INTERIOR AREA (IC1/IC2)
SLIDE-OUT ROOM EXTENSION
There shall be an HWH Space Maker universal level out (ULO) hydraulic room extension on the curbside which shall
extend approximately 31" as measured from the outside of the body. The extendable module shall be approximately
131.5" in length (120.5" interior usable space) and the interior height shall be approximately 11" less than the specified
interior height. The installed module shall provide a water tight seal in both the fully extended and the retracted positions.
The slide-out section utilizes the HWH "Universal Room" mechanism known for its strength and reliability, for rooms up to
4,000 pounds. The floor is suspended above main floor which eliminates the possibility of damage to floor coverings and
when slide-out provides a flat floor. Four-point attachment of the HWH Universal Room Extension draws all four corners in
for positive seal when room is extended or retracted.
Systems that don’t provide a flat floor when fully extended will NOT BE ACCEPTABLE. A manual override shall be
provided in the event of a system failure.
The slide-out section shall be framed with 2" x 2" x 1/4" 6061-T6 alloy aluminum. The frame structure shall be covered
with no less than 1/8" thick 3003-H14 smooth aluminum.
Full width padded foam cushion head bumpers shall be provided in the slide-out. Head bumpers shall be covered with
matching interior vinyl.
There shall be two (2) flashing LED warning lights with red lenses, one (1) at each end of the slide-out section. The lights
shall activate and be visible when the unit is extended.
All electrical wiring installed in the slide-out wall shall run through a boxed type conduit at the lower corner of the system.
All wiring shall be enclosed in a flexible, moisture resistant, reinforced conduit, with proper seal tight connectors and
hardware. Access shall be provided for inspection of all wiring and the slide-out mechanisms.
The slide-out room extension must be able to withstand years of rugged service and wear. For this reason, this design,
metal thickness and attachments must be strictly adhered to. RV type slide-outs or slide-outs using light weight metal or
fiberglass shall not be acceptable.
WINDOW(S)
There shall be two (2) 18"wide x 22" high, double-paned insulated, non-sliding window(s) installed in the entrance door.
Each window shall have dark, reflective Limo type automotive type safety glass mounted in an extruded
aluminum frame. The frame shall have a black anodized finish.
INTERIOR CABINET - OVERHEAD
There shall be three (3) 26" wide overhead cabinet(s) provided on interior. Cabinet(s) shall be constructed of 1/8" smooth
finish aluminum, and painted with a hammer tone powder coat paint finish for a hard durable surface. Paint color shall be
gray.
• The above cabinet(s) shall have lift-up type door(s) with dry-erase outer surface.