Specifications
Vancouver Police Service
Command
Production Specification
SVI #847 Page 64 of 107 September 18, 2012
STREETSIDE INTERIOR AREA (IS3)
MIDDLE ATLANTIC 40U DATA RACK
There shall be one (1) Middle Atlantic Products model # MRK-4026, EIA compliant 19” gangable equipment rack(s),
provided on completed vehicle.
Overall dimensions shall be 76.125”H x 22.0”W x 26.4”D. Useable height shall be 40 rack spaces, useable depth shall be
24”. Fully welded construction shall provide a static capacity of 10,000 lbs. and a UL Listed load capacity of 2,500 lbs.
Rack shall be constructed of the following materials: top and bottom shall be 14-gauge steel, horizontal braces shall be
16-gauge steel, rear door shall be 18-gauge steel and all structural elements shall be finished in a durable black powder
coat.
Rack shall come equipped with two pairs of 11-gauge steel rack rail with tapped 10-32 mounting holes in universal EIA
spacing, black e-coat finish and numbered rack spaces.
Rack shall have removable split rear knockout panels with 1/2”, 3/4”, 1” and 1-1/2” electrical knockouts and top BNC
knockouts for UHF/VHF antenna.
Lightly smoked plexiglass front door with black textured powder coat finish and keylock. The door is capable of hinging on
either the left or the right of the rack.
Integrated fan top includes 4.5" fans, fan guards and proportional speed thermostatic fan controller.
The PD-920R-NS rack mount power distribution unit is equipped with 8 circuit breaker protected rear outlets (NEMA 5-
20R), and one front outlet (NEMA 5-15R). An illuminated combination power switch/circuit breaker is located on the front
panel. UL listed in the US and Canada. Occupies one rack space.
The APC Uninterruptible Power Supply (UPS) provides protection for electronic equipment from utility power blackouts,
brownouts, sags and surges. The UPS filters small utility line fluctuations and isolates electronic equipment from large
disturbances by internally disconnecting from utility line power. The UPS provides continuous power from the batteries
until utility power returns to safe levels or the batteries are fully discharged.
The equipment shall be used to store the following components:
• Four (4) units of Cat 6 Ethernet patching (24 patches per unit). Horizontal cable management required above and
below each unit.
• One (1) unit of video patches to support audio video control router components. Horizontal cable management
required above and below each unit.
• One (1) microwave downlink receiver
• One (1) data satellite receiver
• Two (2) satellite TV receivers
• One (1) rack mount UPS
• One (1) VPD supplied integrated services router
• One (1) audio video recorder
• Four (4) units required to be maintained for installation of storage devices by VPD
• Minimum six (6) additional units required to be maintained for future equipment installations.
• Any additional units required for component, rack fans, heaters, power supply, etc. installation as required in this
specification.