Specifications
Vancouver Police Service
Command
Production Specification
SVI #847 Page 59 of 107 September 18, 2012
ELECTRIC BASEBOARD HEAT
Four (4) Grainger model QMKC2576W (or equal), 240 volt, commercial electric baseboard heaters shall be provided as
follows;
• One (1) one the front wall of the Command Room
• One (1) under the curbside slide-out desk
• One (1) under the streetside Negotiators desk
• One (1) under the curbside Negotiators desk
Baseboard units shall be various lengths from 4' - 6' to fit specified areas. Heaters shall be controlled by wall mounted
thermostat in each area as specified above.
EXHAUST FAN
The apparatus shall have two (2) Fan-Tastic Vent model 6000 RBTA, 12 volt exhaust fan(s) installed in the ceiling of the
body. Each fan shall be wired to an electrical rocker switch located at the entrance door, mounted on the side wall.
• One (1) fan shall be located in the Command Room
• One (1) fan shall be located in the Negotiator Room
The fan switch(es) shall be wired battery direct to allow the thermostatically controlled fans to operate while the apparatus
is parked in storage.
DO NOT ENTER LIGHTING/SIGNAGE
There shall be two (2) non-flashing red LED lights (with supporting signage) provided to indicated when the negotiators
are using the phone system (Truck-lite model 33 or equivalent with clear lens). The lights shall be located:
• One (1) on the exterior of the streetside body, adjacent the side entry door handle. The light shall be provided with a
hooded enclosure to ensure the light is only viewable from the area immediately adjacent to the door opening.
• One (1) on the rear wall of the Command Room, adjacent to the Negotiator Room pocket door, and approximately 12”
down from the ceiling.
The lights shall be tied into the phone at workstation 6 to automatically illuminate when the phone is off the hook.
SMOKE/CO DETECTOR
There shall be two (2) First Alert model SCO5B AA battery powered combination smoke/CO detector(s) provided in the
walk in area(s) of the body. The detectors shall be located as follows:
• One (1) in the Command Room
• One (1) in th eNegotiator Room