Specifications
Vancouver Police Service
Command
Production Specification
SVI #847 Page 105 of 107 September 18, 2012
SATELLITE DISH PRE-WIRE
There shall be a pre-wire provision on the body roof for the installation of a Vancouver Police Department supplied data
satellite dish. The provision shall include open roof space for a 1.2M dish, roof re-enforcement for the additional weight, a
roof mounted sealed junction box, and cable conduit to the specified data rack(s). All wiring between the data rack(s) and
satellite dish shall be the responsibility of Vancouver Police Department.
COMMAND CAMERA SYSTEM
There shall be one (1) Bosch MIC400AL14636N with Pan-Tilt-Zoom and brushless motor technology provided and
installed on the specified pneumatic mast. The camera system shall be a high resolution unit with Day/Night functionality
and a 36x optical zoom lens.
TELESCOPING PNEUMATIC MAST
The vehicle shall be equipped with one (1) Will-Burt 7-42 heavy duty pneumatic powered telescoping mast(s). The mast
shall utilize air from the chassis brake system. Air to operate the telescoping mast must be drawn from a drier system and
be regulated to 20 psig and shall have a back pressure protection valve.
Mast shall be wired to a red flashing warning light in cab visible to the driver to warn when the mast is out of the nested
position.
A pneumatic kit to raise and lower the mast shall include air control valve, 0-160 psig air valve, regulator, 0-30 psig air
gauge.
A 70' Nycoil conduit measuring 1" ID x 16-1/2" OD coil shall be provided for the 7-42 telescopic mast.
The mast shall be of a free standing design (non-guyed) and use high strength, heat treated aluminum alloy tubes and
collars. Each mast section (tube) shall have two full length external keys and nominal .095" wall thickness collars with
matching keyways to maintain directional azimuth.
Each mast section and collar shall be of the low friction synthetic bearings for smooth operation and longer life. Bumpers
shall be supplied to reduce shock on extension and retraction. All exterior aluminum surfaces shall be anodized and
sealed. Fasteners and fittings shall be plated steel or stainless steel for corrosion resistance.
One (1) maintenance and instruction manual shall be provided for the towers on delivery. Wiring schematic, air piping
schematic and installation diagrams shall be provided with the manual. Manufacturer's blueprint of tower, complete parts
list and bill of materials for towers provided with manuals.
MODEL 7-42 SPECIFICATIONS
Nested height tower only:
7'-1"
Extended height tower only:
41'-2"
Normal payload capacity:
150 lbs.
Number of sections:
9
Mast Diameter:
9" - 3"
Mast Volume:
7.2 cu. ft.
Collar type:
Non-locking
Maximum operating pressure:
35 psi
The operational envelope of the mast shall be automatically illuminated by a lookup light whenever the mast assembly is