Vancouver Police Service Command Production Specification Contents INTERNET IN-PROCESS SITE .............................................................................................................................................. 7 VEHICLE STABILITY SUPPLIED WITH CAB/CHASSIS ....................................................................................................... 7 ROADABILITY..................................................................................................................
Vancouver Police Service Command Production Specification RADIO/ANTENNA INSTALLATION ...................................................................................................................................... 33 CAB DOME LIGHT OVERRIDE SWITCH ............................................................................................................................ 33 SEAT BELT COLOR ..................................................................................................................
Vancouver Police Service Command Production Specification STREETSIDE COMPARTMENT - AHEAD OF REAR WHEELS (S2) ................................................................................. 47 STREETSIDE COMPARTMENT - REAR (S3) ..................................................................................................................... 48 UPPER VIDEO COMPARTMENT ........................................................................................................................................
Vancouver Police Service Command Production Specification ROLLING FILE CABINET ..................................................................................................................................................... 65 INTERIOR DESK .................................................................................................................................................................. 65 WALL MOUNTED CONNECTION PANEL ......................................................................
Vancouver Police Service Command Production Specification LINE VOLTAGE ELECTRICAL SYSTEM ............................................................................................................................. 86 DIESEL GENERATOR.......................................................................................................................................................... 86 WARRANTY PERIOD ........................................................................................................
Vancouver Police Service Command Production Specification SATELLITE DISH PRE-WIRE............................................................................................................................................. 105 COMMAND CAMERA SYSTEM ......................................................................................................................................... 105 TELESCOPING PNEUMATIC MAST ..............................................................................................
Vancouver Police Service Command Production Specification INTERNET IN-PROCESS SITE The Bidder shall post and maintain a website where the Vancouver Police Department will be able to view digital images of their apparatus as its being manufactured. The digital images shall be posted once a week starting when the body begins production or when the cab/chassis arrives and shall continue until the final completion of the apparatus.
Vancouver Police Service Command Production Specification CONSTRUCTION DOCUMENTATION The contractor shall supply, at the time of delivery, at least one (1) copy of the following documents: The manufacturers record of apparatus construction details, including the following information: 1) Owner’s name and address 2) Apparatus manufacturer, model, and serial number 3) Chassis make, model, and serial number a) GAWR of front and rear axles and GVWR b) Front tire size and total rated capacity in pounds (kilogram
Vancouver Police Service Command Production Specification OPERATIONS AND SERVICE DOCUMENTATION The Contractor shall deliver with the fire apparatus at least two (2) sets of complete operation and service documentation covering the completed apparatus as delivered and accepted. The documentation shall address at least the inspection, service, and operations of the fire apparatus and all major components thereof.
Vancouver Police Service Command Production Specification CUSTOM OPERATIONS MANUAL The contractor shall supply, at the time of delivery, one (1) printed copy, and one (1) electronic copy of the following documents: In addition to the manufacturers record of apparatus construction details, and the operations and service manuals, a custom operations manual shall be provided including the following information; The operations manual shall be specific to the manufacture of the Vancouver Police Department vehicl
Vancouver Police Service Command Production Specification CARRYING CAPACITY The GAWR and the GCWR or GVWR of the chassis shall be adequate to carry the weight of the completed vehicle when loaded to its estimated in-service weight.
Vancouver Police Service Command Production Specification TESTING ROAD TEST Road test shall be conducted in accordance with this section to verify that the completed apparatus is capable of compliance with Roadability Section. The tests shall be conducted at a location and in a manner that does not violate local, state or provincial or federal traffic laws. The tests shall be conducted on dry, level, paved roads that are in good condition. The apparatus shall be loaded to its estimated in service weight.
Vancouver Police Service Command Production Specification 2. ALTERNATOR PERFORMANCE TEST TEST AT IDLE The minimum continuous electrical load shall be activated with the engine running at idle speed. The engine temperature shall be stabilized at normal operating temperature. The battery system shall be tested to detect the presence of battery discharge current. The detection of battery discharge current shall be considered a test failure.
Vancouver Police Service Command Production Specification UL 120/240 VAC CERTIFICATION The 120/240 volt electrical system shall be third-party, independent, audit-certified through Underwriters Laboratory (UL) to the current edition of NFPA 1901 to perform as listed below; The prime mover shall be started from a cold start condition, and the unloaded voltage and frequency shall be recorded.
Vancouver Police Service Command Production Specification DIELECTRIC VOLTAGE WITHSTAND TEST The line voltage wiring and permanently connected devices and equipment shall be subjected to a dielectric voltage withstand test of 900 volts for one (1) minute. The testing shall be performed after all body work has been completed.
Vancouver Police Service Command Production Specification PAINT LIMITED WARRANTY - TEN (10) YEARS The body shall be free of bubbling or peeling as a result of a defect in the method of manufacture for a period of ten (10) years or 100,000 miles (or 160,934 kilometers), whichever occurs first, starting thirty (30) days after the original invoice date. Pro-rated warranties will not be acceptable. GRAPHICS LIMITED WARRANTY The 3M graphics installation shall be warranted for a period of two (2) years.
Vancouver Police Service Command Production Specification IT ENGINEER DEMONSTRATION The Contractor shall provide an Information Technology (IT) engineer to be present at time of delivery and demonstration for three (3) consecutive days.
Vancouver Police Service Command Production Specification CAB/CHASSIS SPECIFICATION Data Code Price Level Description PRL-03M Data Version M2 PRL-03M (EFF:01/25/12) Weight Front Weight Rear 5,205 3,055 DRL-032 SPECPRO21 DATA RELEASE VER 032 Vehicle Configuration 001-172 004-213 002-004 019-002 003-001 General Service AA1-002 AA6-003 RCE-00F A85-006 A84-1EV AA4-011 AA5-002 AB1-008 AB5-001 995-091 A66-99D A68-99D A63-99D GVWR SVI #847 M2 106 CONVENTIONAL CHASSIS 2013 MODEL YEAR SPECIFIED SET BACK
Vancouver Police Service Command Production Specification Truck Service AA3-025 A88-99D AF6-99D A89-99D AF7-99D RESCUE - STRAIGHT (NON DROP) FRAME NO MAIN DRIVELINE DRIVEN SPLIT-SHAFT PTO EXPECTED TRUCK BODY LENGTH : 22.5 ft EXP EMPTY BODY CG LOC FROM BODY FRT(A89) : 4.0 ft BRAKING-EXPECTED CAB TO BODY CLEARANCE : 3.0 in EXPECTED BODY/PAYLOAD CG HEIGHT ABOVE FRAME "XX" INCHES : 32.0 in Engine 101-2N7 CUM ISB 6.
Vancouver Police Service Command Production Specification Engine Equipment 99C-010 99D-010 105-001 133-004 014-099 124-1E7 292-1D8 290-017 282-001 291-017 289-001 293-058 107-032 108-002 131-013 152-039 128-076 016-1DE 28F-007 239-038 SVI #847 2010 EPA/CARB EMISSION CERTIFICATION NO 2008 CARB EMISSION CERTIFICATION ENGINE MOUNTED OIL CHECK AND FILL ONE PIECE VALVE COVER SIDE OF HOOD AIR INTAKE WITH FIREWALL MOUNTED DONALDSON AIR CLEANER DR 12V 275 AMP 40-SI QUADRAMOUNT PAD ALTERNATOR WITH REMOTE
Vancouver Police Service Command Production Specification 237-1D0 23U-001 30N-003 23Y-001 43X-005 43Y-001 242-001 273-035 276-001 110-003 118-001 266-078 103-004 171-007 172-001 270-016 168-002 360-998 138-010 140-053 134-001 132-004 155-057 SVI #847 RH CURVED VERTICAL TAILPIPE CPILLAR MOUNTED ROUTED FROM STEP 6 GALLON DIESEL EXHAUST FLUID TANK 100 PERCENT DIESEL EXHAUST FLUID FILL STANDARD DIESEL EXHAUST FLUID PUMP MOUNTING LH UNDER CAB DIESEL EXHAUST FLUID TANK LOCATION STANDARD DIESEL EXHAUST FLUID
Vancouver Police Service Command Production Specification Transmission 342-1KD ALLISON 3000 EVS AUTOMATIC TRANSMISSION WITH PTO PROVISION Transmission Equipment 200 60 352-998 343-1G0 NO AUXILIARY TRANSMISSION WTEC CALIBRATION - 5 SPEED EVS WITH AUTO NEUTRAL (PACKAGE 199) 353-022 VEHICLE INTERFACE WIRING WITH BODY BUILDER CONNECTOR MOUNTED BACK OF CAB 34C-001 ELECTRONIC TRANSMISSION CUSTOMER ACCESS CONNECTOR FIREWALL MOUNTED 362-035 CUSTOMER INSTALLED CHELSEA 277 SERIES PTO 363-001 PTO MOUNTING, LH SID
Vancouver Police Service Command Production Specification Front Suspension 620-010 14,600# TAPERLEAF FRONT SUSPENSION 619-005 MAINTENANCE FREE RUBBER BUSHINGS - FRONT SUSPENSION 410-001 FRONT SHOCK ABSORBERS Rear Axle and Equipment 420-265 421-643 424-001 386-076 423-083 433-002 434-003 451-005 440-021 426-1AH 428-030 41T-001 Rear Suspension 622-216 621-007 431-001 888-047 87D-006 910-001 623-002 439-004 SVI #847 RS-23-161 24,000# R-SERIES FIRE/EMERGENCY SERVICE SINGLE REAR AXLE 6.
Vancouver Police Service Command Production Specification Brake System 018-002 490-101 871-001 904-001 412-001 46D-002 413-002 432-003 480-083 479-015 460-008 46A-002 477-006 AIR BRAKE PACKAGE WABCO 4S/4M ABS WITH TRACTION CONTROL REINFORCED NYLON, FABRIC BRAID AND WIRE BRAID CHASSIS AIR LINES FIBER BRAID PARKING BRAKE HOSE STANDARD BRAKE SYSTEM VALVES STANDARD AIR SYSTEM PRESSURE PROTECTION SYSTEM STD U.S.
Vancouver Police Service Command Production Specification Wheelbase & Frame 545-682 546-101 547-001 552-059 55W-009 AC8-99D AE8-99D AE4-99D AM6-99D FSS-0LH FSS-0RH 553-001 550-001 559-001 562-001 572-001 565-002 6825MM (269 INCH) WHEELBASE 11/32X3-1/2X10-15/16 INCH STEEL FRAME (8.73MMX277.8MM/0.344X10.94 INCH) 120KSI 1/4 INCH (6MM) C-CHANNEL INNER FRAME REINFORCEMENT 2425MM (95 INCH) REAR FRAME OVERHANG FRAME OVERHANG RANGE: 91 INCH TO 100 INCH CALC'D BACK OF CAB TO REAR SUSP C/L (CA) : 177.
Vancouver Police Service Command Production Specification 605-017 LEVEL FRAME RAILS (+1%, -0%) WHEN CHASSIS IS LOADED TO FRONT AND REAR SUSPENSION RATINGS Fuel Tanks 204-215 218-005 215-005 212-007 664-001 205-001 122-077 216-020 202-016 50 GALLON/189 LITER SHORT RECTANGULAR ALUMINUM FUEL TANK - LH RECTANGULAR FUEL TANK(S) PLAIN ALUMINUM/PAINTED STEEL FUEL/HYDRAULIC TANK(S) WITH PAINTED BANDS FUEL TANK(S) FORWARD PLAIN STEP FINISH FUEL TANK CAP(S) ALLIANCE FUEL FILTER/WATER SEPARATOR WITH HEATED BOWL
Vancouver Police Service Command Production Specification Cab Exterior 829-075 650-008 678-018 646-009 65X-001 644-004 690-002 727-036 726-002 657-001 575-001 312-043 302-047 311-001 294-046 300-015 744-1BC 797-001 796-001 743-204 729-001 677-016 768-043 661-003 654-011 767-047 663-013 659-019 SVI #847 132 INCH BBC HIGH-ROOF EXTENDED ALUMINUM CONVENTIONAL CAB AIR CAB MOUNTS LH AND RH EXTERIOR GRAB HANDLES WITH SINGLE RUBBER INSERT PAINTED PLASTIC GRILLE ARGENT SILVER HOOD MOUNTED AIR INTAKE GRILLE F
Vancouver Police Service Command Production Specification Cab Interior 707-1AM 706-026 708-026 772-006 691-008 694-010 742-007 680-006 860-004 700-002 701-001 703-005 170-045 130-033 702-002 739-036 285-013 280-007 324-046 655-005 284-045 722-002 756-1E7 760-1E7 711-004 758-014 SVI #847 OPAL GRAY CLOTH INTERIOR MOLDED PLASTIC DOOR PANEL WITHOUT VINYL INSERT WITH ALUMINUM KICKPLATE LOWER DOOR MOLDED PLASTIC DOOR PANEL WITHOUT VINYL INSERT WITH ALUMINUM KICKPLATE LOWER DOOR BLACK MATS WITH SINGLE INSU
Vancouver Police Service Command Production Specification 761-014 BLACK CORDURA PLUS CLOTH PASSENGER SEAT COVER 763-074 3 POINT HIGH VISIBILITY ORANGE RETRACTOR DRIVER AND RH FRONT PASSENGER SEAT BELTS WITH NFPA 1901-2009 COMPLIANT SENSOR AND DASH HARNESS 532-002 ADJUSTABLE TILT AND TELESCOPING STEERING COLUMN 540-015 4-SPOKE 18 INCH (450MM) STEERING WHEEL 765-002 DRIVER AND PASSENGER INTERIOR SUN VISORS Instruments & Controls 732-004 734-004 87L-003 870-001 486-001 840-002 198-025 721-003 149-013 156-02
Vancouver Police Service Command Production Specification 830-017 49B-004 852-002 679-001 746-1A2 747-001 750-002 753-001 810-028 817-001 812-001 162-011 836-015 660-008 304-001 882-018 299-013 298-039 SVI #847 ENGINE AND TRIP HOUR METERS INTEGRAL WITHIN DRIVER DISPLAY ENHANCED STABILITY CONTROL ELECTRIC ENGINE OIL PRESSURE GAUGE OVERHEAD INSTRUMENT PANEL AM/FM/WB RADIO WITH FRONT AUXILIARY INPUT DASH MOUNTED RADIO (2) RADIO SPEAKERS IN CAB AM/FM ANTENNA MOUNTED ON FORWARD LH ROOF ELECTRONIC KPH SPEEDO
Vancouver Police Service Command Production Specification Design 065-000 PAINT: ONE SOLID COLOR Color 980-5A1 CAB COLOR A: L0001EB BLACK ELITE BC 986-020 BLACK, HIGH SOLIDS POLYURETHANE CHASSIS PAINT Certification / Compliance 996-002 CANADA CMVSS CERTIFICATION Secondary Factory Options 999-999 T O T A L SPECIAL NARRATIVE INSTRUCTIONS NEED TO DELETE INTERIOR REAR VIEW MIRROR PLEASE V E H I C L E S U M M A R Y Weight Summary Factory Weight Total Weight I T E M S P R I C E + + N O T Weight Front
Vancouver Police Service Command Production Specification CHASSIS MODIFICATIONS LUBRICATION AND TIRE DATA PLATE A permanent label in the driving compartment shall specify the quantity and type of the following fluids used in the vehicle and tire information: • • • • • • • • • • • • • • • • • Engine oil Engine coolant Chassis transmission fluid Pump transmission lubrication fluid . . (if applicable) Pump priming system fluid, if applicable . .
Vancouver Police Service Command Production Specification ACCIDENT PREVENTION There shall be a placard in the cab seating area which reads, "ALL OCCUPANTS MUST BE SEATED AND BELTED WHEN THE APPARATUS IS IN MOTION". PERSONNEL CAPACITY A label that states the number of personnel the vehicle is designed to carry shall be located in an area visible to the driver.
Vancouver Police Service Command Production Specification SEAT BELT COLOR Section 14.1.3.4 of the NFPA 1901 Standards, 2009 edition, requires all seat belt webbing in cab to be bright red or bright orange in color, and the buckle portion of the seat belt shall be mounted on a rigid or semi rigid stalk such that the buckle remains positioned in an accessible location. SEAT BELT WEB LENGTH - COMMERCIAL CAB Sections 14.1.3.2 and 14.1.3.
Vancouver Police Service Command Production Specification RE-PAINT CAB - ONE COLOR The cab exterior (not including driver and passenger side doors) shall be re-painted with PPG Delfleet Evolution paint. Exterior Color: Black Exterior Paint Number: FBCH 9300 PAINT DOOR JAMBS JOB COLOR Two (2) chassis door jambs will be painted to match the exterior color of the chassis.
Vancouver Police Service Command Production Specification EXTENDED CAB MODIFICATION The extended cab area shall be modified to create an equipment storage area as follows; • • • • • • The rear cab window shall be removed and replaced with a painted panel that shall match the cab color. The painted panel shall be mounted in the cab sheet metal frame with window rubber moulding.
Vancouver Police Service Command Production Specification LEVELING SYSTEM JACK PAD(S) Four (4) Super Dolly Trailer/Bus leveling system pads shall be provided, one (1) for each jack. The pads shall be constructed from injection molded high density polypropylene plastic and measure 15" x 17" x 1". The pads shall be stored in mounting brackets under the apparatus body adjacent to each jack.
Vancouver Police Service Command Production Specification EXTERIOR ALUMINUM BODY The fabrication of the body shall be constructed from aluminum 3003H-14 alloy smooth plate. This shall include compartment front panel, vertical side sheets, side upper rollover panels, rear panels and compartment door frames. The body compartment floors and exterior panels shall be constructed with not less than 3/16" (.187) aluminum 3003H-14 smooth plate.
Vancouver Police Service Command Production Specification BODY SUBFRAME The chassis frame rails shall be fitted with 1/4" custom extruded UHMW polyethylene rail cap to isolate the body frame members from direct contact with chassis frame rails. The body subframe shall be constructed from 6061T6 aluminum alloy tubing. Subframe shall consist of two (2) 2" x 6" x 1/4" aluminum tubes, the same width as the chassis frame rails, NO EXCEPTION.
Vancouver Police Service Command Production Specification STAINLESS STEEL BODY FENDERS The body wheel well openings shall be provided with round radius, polished stainless steel fenderettes. The fenderettes shall be bolted and easily replaceable if damaged. The fenderettes shall be installed using a rubber gasket to reduce buildup of moisture and/or debris. WHEEL WELL LINERS The wheel wells shall be provided with an easily removable polymer, circular inner fender liner.
Vancouver Police Service Command Production Specification MACHINE POLISHED After the force dry/bake cycle and ample cool down time, the coated surface shall be sanded using 1,000, 1,500, and or 3,000 grit sandpaper to remove surface defects. In the final step, the surface shall be buffed then polished to an extra high gloss smooth finish. Total dry film thickness of paint will average between 8.0-12.0 mils.
Vancouver Police Service Command Production Specification COMPARTMENT INTERIOR FINISH The compartment interiors shall be treated with phosphoric acid and then sprayed with an epoxy primer applied 1.0 mil thick. All body seams will be caulked with urethane seam sealer and painted with two (2) coats of textured Zolatone paint. Zolatone catalysts will be added to the Zolatone to help in resisting moisture and provide a more durable finish. Paint color shall be gray.
Vancouver Police Service Command Production Specification LETTERING GRAPHICS PROOF A color graphics proof of the lettering layout shall be provided for approval by Vancouver Police Department prior to installation. The graphics proof shall be submitted to Vancouver Police Department on 8.5" x 11" sheets with front, sides, rear and plan views, each on one (1) sheet. In addition if there is any special art work an additional sheet shall be provided showing all details.
Vancouver Police Service Command Production Specification EXTERIOR COMPARTMENT DOORS HINGED DOOR CONSTRUCTION The exterior compartment doors shall be custom manufactured and built for each compartment. The compartment doors must be able to withstand years of rugged service and wear. For this reason, the compartment door design, metal thickness, and attachments must be strictly adhered to. The compartment doors shall be all aluminum 3003H-14 alloy construction.
Vancouver Police Service Command Production Specification BODY HEIGHT MEASUREMENTS The vertical body dimensions shall be as follows: AHEAD OF REAR AXLE Description A Bottom of Subframe to Top of Body B Bottom of Subframe to Bottom of Body C Vertical Door Opening - (Full Height Compartment) -with roll-up door -with hinged door Vertical Door Opening - (Short Compartment) -with hinged door ABOVE REAR AXLE Description D Vertical Door Opening - Above Rear Wheel -with roll-up door -with hinged door 67.5" 71.
Vancouver Police Service Command Production Specification STREETSIDE COMPARTMENT - FRONT (S1) The interior useable compartment space shall be approximately 70.0" wide. The compartment door opening shall be approximately 63.0" wide. This compartment shall have a horizontally hinged box pan style door fabricated of 1/8" thick smooth aluminum. The inner liner of the door shall be 1/8" thick smooth aluminum with an unpainted finish. The door exterior shall be painted job color.
Vancouver Police Service Command Production Specification STREETSIDE COMPARTMENT - AHEAD OF REAR WHEELS (S2) The interior useable compartment space shall be approximately 70.0" wide. The compartment door opening shall be approximately 63.0" wide. This compartment shall have vertically hinged box pan style doors fabricated of 1/8" thick smooth aluminum. The inner liner of the door shall be 1/8" thick smooth aluminum with an unpainted finish. The door exterior shall be painted job color.
Vancouver Police Service Command Production Specification STREETSIDE COMPARTMENT - REAR (S3) The interior useable compartment width shall be approximately 64.0" wide. The compartment door opening shall be approximately 57.0" wide. This compartment shall have a horizontally hinged box pan style door fabricated of 1/8" thick smooth aluminum. The inner liner of the door shall be 1/8" thick smooth aluminum with an unpainted finish. The door exterior shall be painted job color.
Vancouver Police Service Command Production Specification UPPER VIDEO COMPARTMENT The interior useable compartment width shall be approximately 50.0" wide. The compartment door opening shall be approximately 52.0" wide. This compartment shall have horizontally hinged box pan style doors fabricated of 1/8" thick smooth aluminum. The compartment doors shall be double hinged to allow the top door to fold up and the bottom door to fold down, permitting it to be used as a shelf.
Vancouver Police Service Command Production Specification CURBSIDE COMPARTMENT - FRONT (C1) The interior useable compartment space shall be approximately 70.0" wide. The compartment door opening shall be approximately 63.0" wide. This compartment shall have a horizontally hinged box pan style door fabricated of 1/8" thick smooth aluminum. The inner liner of the door shall be 1/8" thick smooth aluminum with an unpainted finish. The door exterior shall be painted job color.
Vancouver Police Service Command Production Specification CURBSIDE COMPARTMENT - AHEAD OF REAR WHEEL (C2) The interior useable compartment space shall be approximately 70.0" wide. The compartment door opening shall be approximately 63.0" wide. This compartment shall have a horizontally hinged box pan style door fabricated of 1/8" thick smooth aluminum. The inner liner of the door shall be 1/8" thick smooth aluminum with an unpainted finish. The door exterior shall be painted job color.
Vancouver Police Service Command Production Specification CURBSIDE COMPARTMENT - AHEAD OF REAR WHEEL (C3) The interior useable compartment space shall be approximately 70.0" wide. The compartment door opening shall be approximately 63.0" wide. This compartment shall have a horizontally hinged box pan style door fabricated of 1/8" thick smooth aluminum. The inner liner of the door shall be 1/8" thick smooth aluminum with an unpainted finish. The door exterior shall be painted job color.
Vancouver Police Service Command Production Specification SIDE ENTRY DOOR Access to the interior body compartment shall be provided through a side entry door. The door opening shall be approximately 29" wide x 74" high. Construction of the side entry door shall be with 1/8" aluminum exterior smooth plate, the interior door pan being constructed from 1/8" aluminum tread plate. The door shall be hung on full height 14 gauge stainless steel hinge, with a 1/4" stainless steel pin.
Vancouver Police Service Command Production Specification CURBSIDE COMPARTMENT - REAR (C4) The interior useable compartment width shall be approximately 64.0" wide. The compartment door opening shall be approximately 57.0" wide. This compartment shall have a horizontally hinged box pan style door fabricated of 1/8" thick smooth aluminum. The inner liner of the door shall be 1/8" thick smooth aluminum with an unpainted finish. The door exterior shall be painted job color.
Vancouver Police Service Command Production Specification REAR ENTRY DOOR Access to the interior body compartment shall be provided through a rear entry door. The door opening shall be approximately 32" wide x 77" high. Construction of the rear entry door shall be with 1/8" aluminum exterior smooth plate, the interior door pan shall be constructed from 1/8" aluminum treadplate. The door shall be hung on full height 14 gauge stainless steel hinges with 1/4" stainless steel pins.
Vancouver Police Service Command Production Specification PLASTIC FLOOR AND SHELF TILE All compartment floors, shelves, and trays shall be covered with Dri-Dek plastic interlocking grating. • The plastic floor tile shall be black. • The plastic edge trim shall be black. SIDE BODY PROTECTION - RUB RAIL OnScene Solutions rub rails shall be provided below the compartment door openings on both the streetside and curbside.
Vancouver Police Service Command Production Specification WALK-IN INTERIOR FINISH DETAILS DESK, CABINET, CONSOLE FINISH All specified interior desks, cabinets, overhead cabinets, or consoles shall be fabricated from formed 1/8" 3003 H14 alloy smooth aluminum. After fabrication is completed they shall be painted with a hammer tone powder coat paint finish for a hard durable surface. Paint color shall be gray.
Vancouver Police Service Command Production Specification INTERIOR WALKWAY FLOOR There shall be Lonseal, Loncoin-II Flecks installed on the floor substrate. Loncoin II Flecks is a heterogeneous resilient sheet vinyl with a decorative raised coin texture, breathtaking color, and intriguing style. The fleck coloration provides camouflage for simpler maintenance while the raised coin embossing provides enhanced traction.
Vancouver Police Service Command Production Specification ELECTRIC BASEBOARD HEAT Four (4) Grainger model QMKC2576W (or equal), 240 volt, commercial electric baseboard heaters shall be provided as follows; • • • • One (1) one the front wall of the Command Room One (1) under the curbside slide-out desk One (1) under the streetside Negotiators desk One (1) under the curbside Negotiators desk Baseboard units shall be various lengths from 4' - 6' to fit specified areas.
Vancouver Police Service Command Production Specification STREETSIDE INTERIOR AREA (IS1) MAGNETIC SLIDING WHITEBOARD(S) There shall be three (3) magnetic whiteboard(s), approximately 44" wide x 30" tall, located on tracks running along the top surface of the street side lower cabinetry and the interior roof to support. The three (3) magnetic white boards shall be able to be positioned anywhere along the streetside wall of the Command Room from the equipment rack to the front wall.
Vancouver Police Service Command Production Specification REMOVABLE CONFERENCE TABLE The interior of apparatus shall be provided with a conference table approximately 60" long by 36” wide located approximately 30" from the floor. The table shall be designed with a central panel and two (2) fold down sides to minimize the table area when not in use. The table sides shall be able to be lockable in either the folded or horizontal positions.
Vancouver Police Service Command Production Specification STREETSIDE INTERIOR AREA (IS2) INTERIOR CABINET - COUNTER HEIGHT There shall be one (1) interior counter height cabinet(s) provided on interior. Cabinet(s) shall be constructed of 1/8" smooth finish aluminum, and painted with a hammer tone powder coat paint finish for a hard durable surface. Paint color shall be gray. Each cabinet shall be approximately 34"L x 34"W x 42"H.
Vancouver Police Service Command Production Specification TRANSPARENCY FILM HOLDER There shall be one (1) transparency film holder provided on the Command Room ceiling directly adjacent to the specified equipment rack. The holder shall be designed to hold one (1) 44" x 100' roll of Inkpress Transparency Film. The holder shall include a mechanism to cut the film and prevent unwanted unrolling of film. One (1) roll of transparency film shall be provided with the completed apparatus.
Vancouver Police Service Command Production Specification STREETSIDE INTERIOR AREA (IS3) MIDDLE ATLANTIC 40U DATA RACK There shall be one (1) Middle Atlantic Products model # MRK-4026, EIA compliant 19” gangable equipment rack(s), provided on completed vehicle. Overall dimensions shall be 76.125”H x 22.0”W x 26.4”D. Useable height shall be 40 rack spaces, useable depth shall be 24”. Fully welded construction shall provide a static capacity of 10,000 lbs. and a UL Listed load capacity of 2,500 lbs.
Vancouver Police Service Command Production Specification STREETSIDE INTERIOR AREA (IS4) ADDITIONAL SOUND INSULATION In additional to the insulation as specified, the interior area shall include additional sound deadening insulation between the interior walls to isolate the interior area from the balance of the apparatus. SLIDING POCKET DOOR There shall be one (1) sliding pocket door(s) provided on interior of walk-in body area.
Vancouver Police Service Command Production Specification WALL MOUNTED CONNECTION PANEL There shall be two (2) wall mounted connection panel(s) provided in the interior. Panel(s) shall be constructed of 1/8" smooth finish aluminum and painted with a hammer tone powder coat paint finish for a hard durable surface. Paint color shall be gray or black. Each panel shall contain the following items: • There shall be two (2) phone connection(s) with wall plate provided in the front face of the connection panel.
Vancouver Police Service Command Production Specification SMART BOARD PRE-WIRE There shall be a SMART Board pre-wiring provision provided on the streetside wall between the specified monitors. The pre-wire provision shall include all cabling and power to allow for addition of a Vancouver Police Department supplied SMART Board and monitor to be installed after delivery of the apparatus.
Vancouver Police Service Command Production Specification CURBSIDE INTERIOR AREA (IC1/IC2) SLIDE-OUT ROOM EXTENSION There shall be an HWH Space Maker universal level out (ULO) hydraulic room extension on the curbside which shall extend approximately 31" as measured from the outside of the body. The extendable module shall be approximately 131.5" in length (120.5" interior usable space) and the interior height shall be approximately 11" less than the specified interior height.
Vancouver Police Service Command Production Specification UNDER CABINET, RADIO MOUNTING CONSOLE There shall be three (3) under cabinet mounted radio/communication console(s) provided in the interior. The radio cabinet shall provide mounting area for the radios specified. The radio cabinet shall be constructed of 1/8" smooth finish aluminum and painted with a hammer tone powder coat paint finish for a hard durable surface. Paint color shall be gray or black.
Vancouver Police Service Command Production Specification DESKTOP COMPUTER(S) There shall be mounting provisions supplied for three (3) Vancouver Police Department supplied Lenovo M52p 3238 Tiny Form Factor (TFF) (or equivalent) desktop computers. Provisions to include under desk mounting brackets, any miscellaneous cabling, 120 volt AC wiring, and any cable connections.
Vancouver Police Service Command Production Specification CURBSIDE INTERIOR AREA (IC3) There shall be a side entry door located in this area. WALL MOUNTED PHONE There shall be one (1) Vancouver Police Department supplied phone(s) mounted on the front face of the sliding pocket door stub wall. The phone system shall be programmed by the Vancouver Police Department to allow the extension to operate as an intercom between the Command and Negotiator area.
Vancouver Police Service Command Production Specification CURBSIDE INTERIOR AREA (IC4) ADDITIONAL SOUND INSULATION In additional to the insulation as specified, the interior area shall include additional sound deadening insulation between the interior walls to isolate the interior area from the balance of the apparatus. WALL MOUNTED PHONE There shall be one (1) Vancouver Police Department supplied phone(s) mounted on the rear face of the sliding pocket door stub wall.
Vancouver Police Service Command Production Specification INTERIOR ROLL-AROUND CHAIR There shall be two (2) Vecta Rocky 4 Star roll-around office chairs provided at the command desk area.
Vancouver Police Service Command Production Specification LOW VOLTAGE ELECTRICAL SYSTEM- 12 VDC General Any low voltage electrical systems or warning devices installed on the fire apparatus shall be appropriate for the mounting location and intended electrical load. Where wire passes through sheet metal, grommets shall be used to protect wire and wire looms. Electrical connections shall be with double crimp water-tight heat shrink connectors.
Vancouver Police Service Command Production Specification Circuits shall be provided with properly rated low voltage overcurrent protective devices. Such devices shall be readily accessible and protected against heat in excess of the overcurrent device’s design range, mechanical damage, and water spray. Circuit protection shall be accomplished by utilizing fuses, circuit breakers, fusible links, or solid state equivalent devices.
Vancouver Police Service Command Production Specification A voltmeter shall be mounted on the driver’s instrument panel to allow direct observation of the system voltage. Electromagnetic Interference Electromagnetic interference suppression shall be provided, as required, to satisfy the radiation limits specified in SAE J551/1, Performance Levels and Methods of Measurement of Electromagnetic Compatibility of Vehicles, Boats (up to 15 m), and Machines (16.6 Hz to 18 GHz).
Vancouver Police Service Command Production Specification 6. Diagnostics: An output should be able to detect either a short or open circuit. The system should be able report in “real time” a text based message that points the maintenance person to a specific output. Inputs: 1. The inputs shall have the ability to switch by a ground or vbatt signal. 2. The inputs shall be filtered for noise suppression via hardware and software so that RF or dirty power will not trick an input into changing its status.
Vancouver Police Service Command Production Specification CAB CONSOLE A center cab console shall be provided between the Driver's and Officer's seats. Console shall be as large as possible and fabricated of 1/8" smooth aluminum. A textured powder coat paint finish shall shall be provided for durability and finished appearance. The rear portion of the console shall be provided with open top storage for notebooks or maps. Two (2) adjustable dividers shall be provided in the storage area.
Vancouver Police Service Command Production Specification BATTERY SOLENOID Battery switch shall consist of a minimum 200 ampere, constant duty solenoid to feed from positive side of battery. BATTERY CHARGER One (1) Newmar model PT-80 battery charger shall be provided ideal for charging multiple battery bank systems.
Vancouver Police Service Command Production Specification CAB HAZARD WARNING LIGHT A red flashing or rotating light, located in the driving compartment, shall be illuminated automatically whenever the vehicles parking brake is not fully engaged and any of the following conditions exist: • • • • • Any passenger or equipment compartment door is not closed. Any ladder or equipment rack is not in the stowed position. Stabilizer system is not in its stowed position. Powered light tower is not stowed.
Vancouver Police Service Command Production Specification TAIL LIGHTS Rear body tail lights shall be vertically mounted per Federal Motor Vehicle Safety Standards. The following lights shall be furnished: • • • Two (2) Whelen 900 Series 90A00TAR amber LED turn signal lights Two (2) Whelen 900 Series 90R00XRR red LED stop/tail lights Two (2) Whelen 900 Series 90J000CR halogen back-up lights with clear lens Each of the lights above shall be mounted in a 9EFLANGE, chrome finish bezel.
Vancouver Police Service Command Production Specification SIDE SCENE LIGHTS There shall be four (4) Whelen Super LED 900 series (9" x 7") recess mounted scene lights (9SC0ENZR) provided on the upper body. Light quantity shall be divided equally per side. Each light will have twenty-four LED diodes that draw a total of 4.0 amps, with 3,000 lumens. The light shall be an 8-32 degree gradient lens and chrome flange.
Vancouver Police Service Command Production Specification UPPER LEVEL OPTICAL WARNING DEVICES The upper-level optical warning devices shall be mounted as high and as close to the corner points of the apparatus as is practical to define the clearance lines of the apparatus. The upper-level optical warning devices shall not be mounted above the maximum height, specified by the device manufacturer.
Vancouver Police Service Command Production Specification ZONE C - REAR WARNING LIGHTS There shall be two (2) Whelen 900 series (9" x 7") Red/Blue split Linear Super-LED lights (90RB5FCR) provided, one (1) each side. Each light shall have a clear lens and chrome flange. The lights shall be switched at the Vista display in the cab.
Vancouver Police Service Command Production Specification ZONE C - REAR WARNING LIGHTS (LOWER REAR CORNERS) There shall be two (2) Whelen 900 series (9" x 7") Red/Blue split Linear Super-LED lights (90RB5FCR) provided, one (1) each side. Each light shall have a clear lens and chrome flange. The lights shall be switched at the Vista display in the cab.
Vancouver Police Service Command Production Specification LINE VOLTAGE ELECTRICAL SYSTEM DIESEL GENERATOR An Onan model SD 20.0HDKAW-2008A, diesel driven generator shall be installed on the vehicle. The generator shall be installed so that fumes, vapors, heat, and vibrations do not enter the driving or crew compartment. The generator shall be rated at 20,000 watts continuous at 120/240 VAC, 166/83 amps, single phase. Current frequency shall be stable at 60 hertz.
Vancouver Police Service Command Production Specification GENERATOR MOUNTING The generator shall be mounted in a lower exterior compartment on rubber vibration isolators. The compartment shall be reinforced where necessary to hold weight of generator. A valve shall be provided on the generator oil drain outlet and piped to underside of generator compartment with flexible hose and plug. The drain shall be located where easily accessible for generator service.
Vancouver Police Service Command Production Specification MANUALS AND SCHEMATICS Two (2) complete manuals on parts list, maintenance, wiring schematics, hydraulic schematics, circuit boards, voltage regulator board and other components shall be provided on delivery. GENERATOR COMPARTMENT INSULATION The generator compartment shall be provided with heavy duty sound insulation applied to walls and ceiling.
Vancouver Police Service Command Production Specification SHORE POWER INLET - BATTERY CHARGER The above mentioned shore power inlet, and battery conditioner shall be specified in the 12 volt section. SHORE POWER INLET - INVERTER One (1) Kussmaul 30 amp "Super Auto-Eject" shore power inlet shall be furnished and installed. The shore power connection shall automatically disengage from vehicle when chassis ignition is engaged.
Vancouver Police Service Command Production Specification INVERTER A Newmar model 12-3550ICIP inverter shall be provided on vehicle that provides 3,000 continuous watts, 140 A capability, 120 VAC, 60 cycle output from 12 VDC. Inverter shall have a full function remote monitor/control panel.
Vancouver Police Service Command Production Specification LINE VOLTAGE ELECTRICAL SYSTEM GENERAL REQUIREMENTS Stability Any fixed line voltage power source producing alternating current (ac) shall produce electric power at 60 Hz, ±3 Hz when producing power at all levels between no load and full rated power. Any fixed line voltage power source shall produce electric power at the rated voltage ±10 percent when producing power at all levels between no load and full rated power.
Vancouver Police Service Command Production Specification Bonding The neutral conductor of the power source shall be bonded to the vehicle frame. The neutral bonding connection shall occur only at the power source. In addition to the bonding required for the low voltage return current, each body and each driving or crew compartment enclosure shall be bonded to the vehicle frame by a copper conductor. The conductor shall have a minimum amperage rating, as defined in 310.
Vancouver Police Service Command Production Specification Instrumentation If the power source is rated at less than 3 kW, a “Power On” indicator shall be provided. If the power source is rated at 3 kW or more but less than 8 kW, a voltmeter shall be provided.
Vancouver Police Service Command Production Specification Overcurrent Protection Manually resettable over current devices shall be installed to protect the line voltage electrical system components. Power Source Protection A main over current protection device shall be provided that is either incorporated in the power source or connected to the power source by a power supply assembly.
Vancouver Police Service Command Production Specification Wiring Methods Fixed wiring systems shall be limited to the following: 1) Metallic or nonmetallic liquid tight flexible conduit rated at temperatures not less than 194°F (90°C) with stranded copper wire rated for wet locations and temperatures not less than 194°F (90°C) 2) Type SOW, SOOW, SEOW, or SEOOW flexible cord rated at 600 V and at temperatures not less than 194°F (90°C) Electrical cord or conduit shall not be attached to chassis suspension co
Vancouver Police Service Command Production Specification Wiring System Components Only stranded copper conductors with an insulation rated for temperatures of at least 194°F (90°C) and wet locations shall be used. Conductors in flexible cord shall be sized in accordance with Table 400.5(A) of NFPA 70. Conductors used in conduit shall be sized in accordance with 310.15, “Ampacities for Conductors Rated 0–2000 Volts,” of NFPA 70. Aluminum or copper-clad aluminum conductors shall not be used.
Vancouver Police Service Command Production Specification Wiring Schematics An "As-Built" Wiring diagrams for line voltage systems shall be provided to include the following information; a) b) c) d) e) f) g) Pictorial representations of circuit logic for all electrical components and wiring Circuit identification Connector pin identification Zone location of electrical components Safety interlocks Alternator–battery power distribution circuits Input/output assignment sheets or equivalent circuit logic impl
Vancouver Police Service Command Production Specification 120/240 VAC SCENE LIGHTING COMMAND LIGHT - KNIGHT TOWER The apparatus shall be equipped with one (1) all-electric floodlight tower(s). The unit shall not require tapping into vehicle braking system to be operated, eliminating the chance for vehicle brake problems. Hydraulic or pneumatic type floodlights are not acceptable alternatives to the all-electric light tower specified. NO EXCEPTIONS.
Vancouver Police Service Command Production Specification INFORMATION TECHNOLOGY (IT) SYSTEMS All information technology systems specified below shall be supplied, installed, and supported by the contractor including, but not limited to the design, inter-connecting wiring, and integration of all specified systems.
Vancouver Police Service Command Production Specification 'VERTEX' VHF RADIO WITH GPS TRACKING There shall be one (1) 220MHz 'Vertex' VHF radio with GPS tracking provided and installed at workstation 1, next to the tactical radio. The installation shall include the antenna, wiring to antenna, and wiring to the headset switch. MARINE RADIO There shall be one (1) ICOM IC-M604B 5.
Vancouver Police Service Command Production Specification TV SATELLITE ANTENNA One (1) KVH Trac Vision model R6DX "In-Motion" satellite receiver shall be provided on roof of apparatus body. This satellite receiver is designed exclusively for mobile users (RV's, boats, buses). The KVH Trac Vision R6DX is 14.5" H x 32" Dia, and weighs 33 pounds. The R6DX satellite receiver is equipped with an automatic controller so that the antenna automatically aims at the satellite.
Vancouver Police Service Command Production Specification BOSCH AUDIO/VIDEO RECORDER There shall be one (1) Bosch DVR-650-16A200 Digital Video Recorder with internal DVD writer, 16 channels, and 2 TB storage provided and installed on completed vehicle. The Bosch 600 series offers high-quality, real-time digital recording on up to 16 channels. View and control cameras, handle alarms, and check device status all through one convenient interface.
Vancouver Police Service Command Production Specification Wi-Fi NETWORK – EXTERNAL/INTERNAL ACCESS POINT There shall be one (1) one (1) Cisco AIR-CAP1552E-A-K9 external access point and recommended three (3) antennas to provide wi-fi network access to the exterior of the vehicle.
Vancouver Police Service Command Production Specification PROPERTY TAG PRINTER There shall be one (1) Vancouver Police Department supplied Zebra GK420T (or equivalent) property tag printer in the Command Room. The exact printer location shall be determined at the pre-build meeting. The following shall be provided with the printer installation: • • Two (2) circuit labeled RJ-45 plugs with shielded CAT6 cabling that terminates at the rack mount patch panel with 12’ of slack per cable.
Vancouver Police Service Command Production Specification SATELLITE DISH PRE-WIRE There shall be a pre-wire provision on the body roof for the installation of a Vancouver Police Department supplied data satellite dish. The provision shall include open roof space for a 1.2M dish, roof re-enforcement for the additional weight, a roof mounted sealed junction box, and cable conduit to the specified data rack(s).
Vancouver Police Service Command Production Specification MAST MOUNTING - EXTERNAL The above telescoping mast shall be mounted using an external mounting kit attached to the rear body panel. The mast shall be enclosed with a removable 3/16" smooth aluminum enclosure located on the rear of the body extending from bumper level upward to enclose mast. 2" x 2" x 1/4" angles shall be welded to rear body panel for attachment of enclosure to body.
Vancouver Police Service Command Production Specification EQUIPMENT PAYLOAD WEIGHT ALLOWANCE In compliance with NFPA 1901 standards, the special service vehicle shall be designed for an equipment loading allowance of 4,000 lbs. of Vancouver Police Department provided loose equipment based on a 30,001 - 40,000 pound gross vehicle weight rating.