Owner's Manual
EXP1240 Admin Guide, Version 2.0
Proprietary and Confidential
Chapter: EXP1240 Administration Interface
59
Parameters
Description
Idx
System counter
IPEI
Repeater unique DECT identifier
RPN
SINGLE CELL SYSTEM:
The base has always RPN00, first repeater will then be RPN01, second repeater
RPN02 and third RPN03 (3 repeaters maximum per base)
MULTI CELL SYSTEM:
Bases are increment by 2^2 in hex, means first base RPN00 second base RPN04
etc., in between RPN01, 02, 03 addressed for repeaters at Primary base and 05,
06, 07 addressed for Secondary base (3 repeaters maximum per base)
DECT sync source
Select the
base or repeater the rep
eater has to be synchronized to.
5.13.1.2 Local Automatic
Repeater controlled by auto detects best base signal and auto assign RPN. The RPN and DECT sync source
are greyed out.
The repeater RPN is dynamic assigned in base RPN range.
With local automatical mode repeater on repeater (chain) is not supported.
5.13.2 Register Repeater
Adding a repeater makes it possible to register the repeater. Registration is made by select the repeater
and pressing register repeater. The base window for repeater registration will be open until the registration
is stopped. By stopping the registration all registration on the system will be stopped inclusive handset
registration.