Set up Tamper Function
The Home Unit tamper switch is located at rear side of Home Unit and should be pressed for detection.
Once the Home Unit is moved to have tamper status changed, the Home Unit will report periodical tamper event
with loud beep sound. The way to stop event reporting and beep sound is sending SMS command of “ALARMOFF”
or hardware reset.
As Tamper event is triggered, the device will send TT reports to the server according to the related setting.
There are two types of command, the short one is for toggling the function quickly and the long one is for setting
up all the parameter
SMS Setup Format:#USERNAME,Password,Function Mode,ON/OFF,Report Interval,Detection
delay time*
SMS Command: #username,0000,tamper,1*
#username,0000,tamper,1,60,3*
COTA Setup format<@PCswtamper>,<ON/OFF>,<Report Interval>,<Detection delay time>
COTA Command: @PCswfbr,1,60,3
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
tamper
“tamper defines the Tamper report setup mode
1
ON/OFF switch. (1: ON, 0: OFF)
60
TT Report interval (60 sec.). The range is 15 to 65000.
3
Detection delay time (Unit : Second)
Once tamper status have been changed, it will have the delay time to trigger the TT
event to avoid the false alarm.
Generally this value has no need to be changed.
*
End sign.
Table37: Tamper Function Setup Format Description