User's Manual

Table Of Contents
Set up Auto Reboot Time
User can use the following commands below to set the device’s auto reboot for clean up the system status
regularly.
Setup Format: #USERNAME,Password,Function Mode,Intervals (30 min.) *
Command: #USERNAME,0000,rst,48 *
SMS/ COTA Command
Description
#
Start sign.
USERNAME
Default ID of the device.
If you have changed the user name, please use the updated one.
0000
Default password.
If you have changed the password, please use the updated one.
rst
“rst” defines the auto reboot mode
48
30 minutes as a unit. The range is 0 to 99. 0 is disable.
Example: 48 means 24hr reboot once
*
End sign.
Table25: Auto Reboot Time Setup Format Description
Situation
Message Reply
Setup Succeeds
[username] + Auto Reset is defined.
[username] + Auto Reset is disabled.
Incorrect username or
password,
Incorrect command format
[username] + command error
Table26: Auto Reboot Time Setup Response Description