User's Manual
Table Of Contents
- Copyright © 2020 San Jose Technology, Inc. All Rig
- This document contains information that is the pr
- 2
- Document Amendments
- Specification
- Package Contents
- Front View
- SJ-205HAB Quick START/Setting Guide
- STEP 1: APN Identification. Ensure APN Name, APN u
- STEP 2: Send SMS command to device (Check the IMEI
- STEP 3: Send SMS command to device to set up APN:
- default: #username,0000,3,internet,,*(if empty, le
- STEP 4: Send SMS command to point to TCP server: #
- STEP 5: Send SMS command to device to report via T
- SETP 6: Set RTC Time:#username,0000,setrtc,1610121
- 10
- Command Setup for SJ-205HAB
- Change User Name
- Change Password
- Request IMEI Number
- Set up APN for mobile network Service
- Set up URL
- Set up TCP ACK function
- Set up Phone Book List
- Set up Location Auto Report Mode
- Set up Answer Call Mode
- Set up Mandatory Polling report
- Set up Route for Data Transmission
- Get Pairing Information
- Set up Auto Reboot Time
- Set up TCP/UDP Server Address
- Set up Turbo Link Mode
- Set up Command By GPRS
- Set up Device Position
- Set up RTC time
- Set up Tamper Function
- Set up Vibration Detection Function
- Set up Alarm OFF
- Disable the beep sound when alarm event is trigge
- Set up RF power of Home unit
- Set up AES 128 Encryption
- Set up FOTA (Over-the-Air Technology)
- Set up paired with the bracelet (NB5)
- Set up unpaired with the bracelet (NB5)
- IDRST (Clear all of the idpair at the same time)
- RF Command
- Erase the Backup Data(Clear the flash memory)
- Setup buzzing when receiving RF signal
- Setup RFall feature
- Set up Low Power reminder
- Appendix 1: Tracker Event List
- 47
- 48
- 49
- In order to expedite the SANAV repair process, cus
- 1.Neglect, misuse, or abuse, such as incorrect testi
- 2.Placement of unit in extreme environments beyond t
- 3.Subjugation of unit to disassembling, soldering, a
- 4.Any incidental or consequential losses or damages
- 5.Disaster, accidents, use of any inauthentic substi
- 50
- 空白页面
Table 1: User Name Change Format Description
Table 2: User Name Change Response Description
11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.)
Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com
12
w
w
w
w
w
w
.u
.
n
sa
ic
n
tr
a
o
v
n
.
.
c
c
o
o
m
m
© Unictron Technologies Corp.
All specifications subject to change without notice.
Change User Name
Generally, SMS command execution needs correct user name with password, or it will remain the same setting.
The SMS command default user name is “username”. It can be changed by following the command format.
For example, entering the SMS command as the following allows user to change the user name from “username”
to a new user name “SANAV”.
Only enter new command with new user name after it has been changed.
Setup Format: #「username」,「Password」,「Function Mode」,「New User Name」*
Command: #username,0000,1,SANAV *
SMS/ COTA Command
Description
#
Start sign.
username
Default username of the device.
0000
Default password.
If you have changed the password, please use the updated one.
1
Mode 1 defines user name setup mode.
SANAV
New user name changed by the user.
At the maximum of 16 characters, including a~z,A~Z,0~9, @ - _ / .!%&
Please note whether the letters are capitalized or lowercased when
sending the command.
*
End sign.
Situation
Message Reply
Setup Succeeds
[username] + Device username is updated.
Setup Fails
[username] + Device username setup fail!
Incorrect username or
password,
Incorrect command format
[username] + command error