SANAV SJ-205HAB Home Unit User Manual Part Number: SJ-205HAB Doc Type : User Manual Doc Id: WI-RD-E-047 Reversion : V1.0 Copyright © 2020 San Jose Technology, Inc. All Rights Reserved. This document contains information that is the property of SANAV.
Document Amendments............................................................................................... 5 SJ-205HAB Hardware General Introduction......................................................... 6 Specification...................................................................................................................... 6 Package Contents............................................................................................................7 Front View..........................
© Unictron Technologies Corp. All specifications subject to change without notice. Appendix 2: Report Data Output Format............................................................ 48 Appendix 3: NB5 & RF Within SJ-205HAB Range(RF Tag event)............... 49 Warranty Regulation.................................................................................................... 50 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.
Introduction SANAV SJ-205HAB is a low-powered, more compact version of 2G/3G tracker targeting the animal or asset tracking market. Moving targets can be tracked in real-time through internet or specified terminals. The device can communicate with the server through 2G/3G networks, to provide emergency & power alerts, geofencing, remote monitoring, and automatic back-up regarding tracking history.
Revision 1.0 5 Date 2020/10/26 Comments Formal release © Unictron Technologies Corp. All specifications subject to change without notice. Document Amendments 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com www.unictron.com www.sanav.
Specification Specifications Electrics Data RF Frequency: 436.8MHz Antenna Embedded GSM and RF Antenna GSM Frequency GSM/GPRS/EDGE: Quad band 850/900/1800/1900MHz UMTS/HSPA+: Five band 800/850/900/1900/2100MHz GSM Module Cinterion EHS6 Memory Built-in 32M X 8bit NAND FLASH © Unictron Technologies Corp. All specifications subject to change without notice.
SJ-205HAB x 1 Adapter © Unictron Technologies Corp. All specifications subject to change without notice. Package Contents AC Adapter x 1 100~240V AC / 1.2A Note: Connect Power Cord to AC Adapter to be a whole power charging solution. 7 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com www.unictron.com www.sanav.
© Unictron Technologies Corp. All specifications subject to change without notice.
Power Supply Connect 12V DC Input 9 © Unictron Technologies Corp. All specifications subject to change without notice. Charging SJ-205HAB 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com www.unictron.com www.sanav.
STEP 1: APN Identification. Ensure APN Name, APN username and APN password for GSM SIM Card Cell carrier. Wrong APN setting will cause the device unable to report via internet service.
SJ-205HAB currently provides SMS command and COTA (TCP) command for remote setup. User can setup the SJ-205HAB by following the instructions shown in following chapters via SMS/COTA. Key the specific SMS message in your cellular phone and send it to the SIM number of SJ-205HAB. The setup messages are showed in the following sections. 1: The default setting: Default ID is “USERNAME”. Please read chapter Change User Name to desired ID. Default password is “0000”.
Generally, SMS command execution needs correct user name with password, or it will remain the same setting. The SMS command default user name is “username”. It can be changed by following the command format. © Unictron Technologies Corp. All specifications subject to change without notice. Change User Name For example, entering the SMS command as the following allows user to change the user name from “username” to a new user name “SANAV”.
Generally, SMS command execution needs correct user name with password, or it will remain the same setting. The SMS command default password is “0000”. It can be changed by following the command format. © Unictron Technologies Corp. All specifications subject to change without notice. Change Password For example, entering the SMS command as the following allows user to change the password from “0000” to a new password “1111”. Only enter new command with new password after it has been changed.
IMEI stands for International Mobile Equipment Identification, a unique number for identifying mobile devices validity in 2G/3G network. As above stated, each device has a unique IMEI number. Entering the command as the following allows user to check the IMEI number of the device for network registration and tracking. Setup Format: #「USERNAME」,「Password」,「Function Mode」* Command: #USERNAME,0000,imei* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device.
Access Point Name (APN) is a protocol that typically allows a user's device to access the internet using the mobile phone network. It is a network identifier used by a mobile device when connecting to a 2G/3G carrier. The carrier will then examine this identifier to determine what type of network connection should be created. For uploading the data to a web server, a set of 2G/3G APN from your 2G/3G network is required. Various © Unictron Technologies Corp.
Message Reply Setup Succeeds [username] + Device GPRS APN is updated. Setup Fail [username] + Device GPRS APN setup Fail! Incorrect username or [username] + command error password, Incorrect command format Table 8: APN Setup Response Description © Unictron Technologies Corp. All specifications subject to change without notice. Situation 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com 16 www.
This SMS command instructs the device to transmit GPS (GPRMC) positioning data to a specified URL (Uniform Resource Locator) or IP address of HTTP protocol server for real time GPS tracking. Entering the SMS command as the following allows user to changes the address to “http://www.sanavtw.com/uploadM1.php”. The address will be assigned to receive the GPS data sent by the device. Then you can link to Sanav Test Website: https://www.sanavtw.com to view your device data.
Message Reply Setup Succeeds [username] + Device IP/Domain is updated. Setup Fail [username] + IP/Domain setup Fail! Incorrect username or [username] + command error password Incorrect command format Table 10: URL or IP Setup Response Description © Unictron Technologies Corp. All specifications subject to change without notice. Situation 11F., No.2, Sec. 4, Jhongyang Rd., Tucheng Dist., New Taipei City 236, Taiwan (R.O.C.) Tel: 886-2-22694456|Fax: 886-2-22694451|service@unictron.com 18 www.
The Home Unit has TCP ACK function to make sure no data lose. Use this command to toggle this feature. Setup format: #, , , , * Command: #username,0000,tcpack,1,10* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. Default password. If you have changed the password, please use the updated one. 0000 tcpack Function code.
© Unictron Technologies Corp. All specifications subject to change without notice. Set up Phone Book List There are three main purposes of Phone Book List setup: The Home Unit can save 10 phone numbers for receiving or sanding SMS.
© Unictron Technologies Corp. All specifications subject to change without notice. Set up Location Auto Report Mode Generally, the device will generate GPS (GPRMC) data and report to server, specified cellular phone or network routes. Retrospective Location Mode setup can enable the device report GPS data automatically during a period of time. Use this command to set up the frequency of Retrospective Location Mode. The device can report according to time interval.
User can use Answer Call (Voice Mode) command to define the response when MU-201 S3 is receiving an incoming call. The device can answer the call automatically or hang up the call and send current location message. Setup Format: #「USERNAME」,「Password」,「Function Mode」, 「Mode」* Command: #USERNAME,0000,8,1* Note: If user has enabled “Security Phone Book” function, MU-201 S3 will verify whether the caller’s number is in the Security Phone Book. If not, MU-201 S3 will not react to the incoming call.
The user can send the SMS/COTA polling according to the shown example to get desired information. It defines the report format when you set SMS polling. Setup Format: #「USERNAME」,「Password」,「Function Mode」* Command: #USERNAME,0000,10* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. Default password. If you have changed the password, please use the updated one.
© Unictron Technologies Corp. All specifications subject to change without notice. Set up Route for Data Transmission User can follow the instructions below to set the device’s data transmission via HTTP/TCP/UDP or SMS routes. Please confirm the back-end server protocol type and corresponding URL or IP address (with port number if required) before setup. There are 2 main protocols available for transmitting route setup: 1. HTTP: Hypertext Transfer Protocol.
Use this SMS/COTA command to get pairing device ID and status. Setup Format: #「USERNAME」,「Password」,「Function Mode」* Command: #USERNAME,0000,apstatus* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. Default password. If you have changed the password, please use the updated one. 0000 apstatus “apstatus” defines the get pairing information mode * End sign. © Unictron Technologies Corp.
User can use the following commands below to set the device’s auto reboot for clean up the system status regularly. Setup Format: #「USERNAME」,「Password」,「Function Mode」,「Intervals (30 min.) 」* Command: #USERNAME,0000,rst,48 * SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. © Unictron Technologies Corp. All specifications subject to change without notice. Set up Auto Reboot Time If you have changed the user name, please use the updated one. 0000 Default password.
User can use the following commands below to set the device’s GPS (GPRMC) positioning data to a specified IP address and port for real time tracking. Entering the SMS command as the following allows user to change the address to specified IP and port. The IP address will be assigned to receive the GPS data sent by the device. Setup Format: #「USERNAME」,「Password」,「Function Mode」, 「TCP/UDP server address」* Command: #USERNAME,0000,18,220.128.123.1:7878 * Or #USERNAME,0000,18,icare-u.com.
User can use the following commands below to set the device to maintain network connection or disconnect after reporting data. Setup format:#「USERNAME」,「Password」,「Function mode」, 「ON/OFF」* Command: #USERNAME,0000,trb,0* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. © Unictron Technologies Corp. All specifications subject to change without notice. Set up Turbo Link Mode If you have changed the user name, please use the updated one. 0000 Default password.
Use this SMS command to setup sending commands over the network. Setup Format: #「USERNAME」,「Password」,「Function Mode」,「0/1」,「IP: Port」* Command: #USERNAME,0000,cmdbygprs,0,202.39.31.179:13377* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. Default password. If you have changed the password, please use the updated one.
© Unictron Technologies Corp. All specifications subject to change without notice. Set up Device Position User can use the following commands below to set the device positon. Setup Format: #「USERNAME」,「Password」,「Function Mode」,「Latitude」,「N/S」,「Longitude」,「E/W」* Command: #username,0000,gpspos,2458.0000,N,12136.0000,E* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. Default password.
User can use the following commands below to set the RTC time. SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「YYYY&MM&DD&TTTTTT」* Command: #username,0000,setrtc,150115115000* COTA Setup format:<@PCswrtc>, COTA Command: @PCswsetrtc,170528170501 © Unictron Technologies Corp. All specifications subject to change without notice. Set up RTC time SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device.
The Home Unit tamper switch is located at rear side of Home Unit and should be pressed for detection. Once the Home Unit is moved to have tamper status changed, the Home Unit will report periodical tamper event © Unictron Technologies Corp. All specifications subject to change without notice. Set up Tamper Function with loud beep sound. The way to stop event reporting and beep sound is sending SMS command of “ALARMOFF” or hardware reset.
The Home Unit has built-in vibration detection function. Once the Home Unit is moved and detected by vibration sensor, the Home Unit will report periodical vibration event with loud beep sound. This MT event which generates MT reports will end when the home unit stops moving. There are two types of command, the short one is for toggling the function quickly and the long one is for setting up all the parameter © Unictron Technologies Corp. All specifications subject to change without notice.
© Unictron Technologies Corp. All specifications subject to change without notice. Set up Alarm OFF The Home Unit has alarm off function to disable all current alarm reporting and return to normal status as the following: Rear Side Tamper Switch (TT) Once the alarm off command is sent, the Home Unit will stop all current alarm reporting (alarm status). Note that the device still is detecting violation event.
© Unictron Technologies Corp. All specifications subject to change without notice. Disable the beep sound when alarm event is triggered When the alarm events such as MT event are triggered, SJ-205HAB (Home Unit) will generate the beep sound during the event until it has received the “Alarmoff” Command. We can disable this beep sound. The device still alarms as the event has been triggered but without beep sound While this feature is disabled. Use this command to toggle this feature.
© Unictron Technologies Corp. All specifications subject to change without notice. Set up RF power of Home unit The ankle bracelet RF transmit power can be set for HAB (Home Unit) curfew range adjustment as well as the Home Unit RF transmit power. RF transmit power: There are totally 8 levels of RF transmit power that can be set. The stronger the RF transmit power is, the wider the curfew range would be. We always adjust the level of RF transmit power for both the bracelet.
The Home Unit has data encryption function to protect the transmitted data. Use this command to toggle this feature. SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,* SMS Command: #username,0000,aes,1* © Unictron Technologies Corp. All specifications subject to change without notice. Set up AES 128 Encryption SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. 0000 Default password.
The Home Unit provides OTA upgrade function. Put the upgrade file on the server and update the device through SMS command. SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「File URL」* SMS Command: #username,0000,fota, http://220.128.123.1:30000/FW_file.txt* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. 0000 Default password. If you have changed the password, please use the updated one.
© Unictron Technologies Corp. All specifications subject to change without notice. Set up paired with the bracelet (NB5) IDPAIR (Pair) The Home Unit can detect if the bracelets or the extenders are in the RF Range. However, the bracelet’s HAID and the extender’s ID should be set to the Pair-list (idpair) which is restored in the SJ-205HAB. We send this “Idpair” command to SJ-205HAB for configuring this setting. There are 20 sets of HAID that can be set, including bracelet’s and the extender’s.
IDUNPAIR (Unpair) Use this “Idunpair” command to clear the pairing. For instance, when SJ-205HAB receives this command and there is a pair number(I0251) in the Pair-list, then this pair number will be deleted. SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「Bracelet HAID」* SMS Command: #username,0000,idunpair,I0251* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. 0000 Default password.
Use this “Idrst” command to clear all the pairing number in the list which is restored in Home Unit. SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」* SMS Command: #username,0000,idrst* SMS/ COTA Command Description # Start sign. USERNAME Default ID of the device. If you have changed the user name, please use the updated one. 0000 Default password. If you have changed the password, please use the updated one.
The Home Unit can forward RF command to set the bracelet. SMS Setup Format: #「USERNAME」,「Password」,「Function Mode」,「Device ID」,「Function」,「Value」* There are three function can use. RT Set transmission time frequency. Range is 1 ~ 999 sec Example: #username,0000,rfcmd,I0251,rt,60* PW Set RF power. Range is 1 ~ 8 Example: © Unictron Technologies Corp. All specifications subject to change without notice. RF Command #username,0000,rfcmd,I0251,pw,8* AC Set alarm off function.
The device reports GPRMC data to the server/cell phone normally via 3G mobile network. When the 3G is not in service or the 3G signal strength is poor, the GPRMC data will not be able to report to the server. They will be saved to flash memory as backup and back to the server when 3G service is recovered. User can use this command to erase the logged (historical) GPRMC data stored at the flash memory of the device.
© Unictron Technologies Corp. All specifications subject to change without notice. Setup buzzing when receiving RF signal As this feature is on, the Home Unit will generate a buzz sound while receiving RF signal. We usually use this feature as a purpose of testing so that is easier for testers to make sure whether there is a RF connection or not. The default setting is OFF.
As this feature is on, the Home Unit will receive all of the bracelets nearby without pairing in advance. We usually use this feature as a purpose of testing; therefore the default setting is OFF. Generally, we recommend pairing the bracelet while monitoring in order to prevent from receiving unnecessary data. However, we reserve this feature for the necessary conditions.
The user can set the SMS/COTA command to alert user if the battery voltage is low or automatically shut down system when the battery voltage reaches a certain threshold . Setup Format: #「USERNAME」,「Password」,「Function Mode」, 「Voltage Value 1」, 「Voltage Value 2」* Command: #USERNAME,0000,LP,3650,50* SMS/ COTA Command Description # Start sign. user name Default ID of the device. If you have changed the user name, please use the updated one. Default password.
This table shows the different events/ messages sent from the device. There are more than 9 different situations that can trigger the device to respond to positioning commands and tracker status messages as the following. Note: Any event marked with the letter “B” represents data which failed to send through specified route due to priority or mobile network service issue. Check whether the data is sent after network issues are cleared.
1 2 3 4 5 6 7 8 HAB 357042062420808 $GPRMC 132152 A 2458.973 N 12125.66 HAB 357042062420808 $GPRMC 134914 A 2458.973 N 12125.66 9 10 11 12 E 0 0 300620 A*46 E 0 0 300620 A*4A 16 17 18 19 13 14 20 AUTO RFIN I0001 19 8 -74 15 21 22 23 N0000 M18 4079mV N0006 M19 4087mV Field Description Field Description 1 Device Type 16 Event 2 GSM IMEI 17 RF Identification number 3 Log header 18 RF Tag Event ; see appendix 3 4 UTC Time ; 11:08:57.
1(hexadecimal) 9(hexadecimal) 0 0 0 1 1 0 0 1 Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 if charge not LP2 completed (Extremely FBR (Strap ACK bit Device Tamper) (Reserved) Tamper UNPLUG (Disconnect from main power) Charging when unplug Low Power) Low Battery © Unictron Technologies Corp. All specifications subject to change without notice.
Warranty Time Period and Repair Coverage SAN JOSE TECHNOLOGY, INC. provides a 1-year (12-month) product warranty for SANAV products purchased directly from SAN JOSE Technology or authorized dealers effective from date of unit purchase. If the equipment is defective or malfunctions during the 1-year warranty period, SAN JOSE Technology will either repair or replace the unit free of charge for the customer. SANAV’s repair service will include necessary adjustments, remanufacturing, and replacements.
FCC Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.