Service manual
1-34 June 21, 2004
GENERAL NP88 FLEX
Troubleshooting
Circuit Checks
Refer to the applicable receiver section in this publication for identification of the
components and test points referenced in the following sections.
Oscillator Warp Range
The oscillator wa rp range is the difference between the highest and lowest IF
frequencies obtained while varying the Oscillato r Trimmer Capacitor.
1. Ensure a battery with a minimum output of 1.3 volts is installed in the pager.
2. Refer to Tables 1-9 and 1-10 for lists of recommended test equipment.
3. Refer to the applicable schematic waveform and voltage information in the
appropriate supplement.
4. Ensure the pager is in self-diagnostic mode 5 (refer to "Self-Diagnostic Fea-
ture").
5. Monitor metering point M1 with a frequency counter.
6. Set the RF signal generator to the pager’s exact carrier frequency and at a
sufficient level to trigger the frequency counter.
7. Tune the Oscillator Trimmer Capacitor a nd note the highest and lowest IF
frequency displayed by the counter. The difference must be between 7 and 15
kHz.
Mixer Injection Voltage Measurement
1. Ensure a battery with a minimum output of 1.3 volts is installed in the pager.
2. Refer to Tables 1-9 and 1-10 for lists of recommended test equipment.
ACPB-930353-A
Figure 1-31. 10 dB Rise Measurement
N
First and second oscillator activities and injections must be observed using a
high-impedance probe.