Specifications

5 - 19
5 Communications Data for Modbus
E5C-T Digital Controllers Programmable Type Communications Manual (H186)
5-1 Variable Area (Setting Range) List
5
Address
Parameter name Setting (monitor) value Level
4 bytes 2 bytes
1900 3900 Program 0 Segment 0
Typ e
H'00000000 (0): Ramp
H'00000001 (1): Soak
H'00000002 (2): Step
Program
setting
1902 3901 Program 0 Segment 0 SP SP lower limit to SP upper limit
1904 3902 Program 0 Segment 0
Slope
H'00000000 to H'0000270F (0 to 9999)
1906 3903 Program 0 Segment 0
Time
H'00000000 to H'00009959 (0.00 to 99.59) (hours, minutes)
H'00000000 to H'00009959 (0.00 to 99.59) (minutes, seconds)
1908 3904 Program 0 Segment 1
Typ e
Same as for segment 0.
to to
1910 3908 Program 0 Segment 2
Typ e
to to
1918 390C Program 0 Segment 3
Typ e
to to
1920 3910 Program 0 Segment 4
Typ e
to to
1928 3914 Program 0 Segment 5
Typ e
to to
1930 3918 Program 0 Segment 6
Typ e
to to
1938 391C Program 0 Segment 7
Typ e
to to
1940 3920 Program 0 Segment 8
Typ e
to to
1948 3924 Program 0 Segment 9
Typ e
to to
1950 3928 Program 0 Segment 10
Typ e
to to
1958 392C Program 0 Segment 11
Typ e
to to
1960 3930 Program 0 Segment 12
Typ e
to to
1968 3934 Program 0 Segment 13
Typ e
to to
1970 3938 Program 0 Segment 14
Typ e
to to
1978 393C Program 0 Segment 15
Typ e
to to
1980 3940 Program 0 Segment 16
Typ e
to to
1988 3944 Program 0 Segment 17
Typ e
to to