Specifications
Rotary Switch
Below table indicated for information about the rotary 
switch positions.
Continuity measurement.
Capacitance measurement.
measurement.
AC or DC current measurement range
from 0.1mA to 10.000A.
AC or DC current measurement range 
from 0.001mA to 800.00mA.
Functional Buttons(1)
Below table indicated for information about the functional 
button operations.
Function
Turn the continuity buzzer on and 
off in the Resistance measurement 
mode.
Continuity 
 Test
Power-Up 
 Option
Press while turning on the 
Meter to disable the beeper 
of pressing any button.
 LCD 
Symbol
Measure 
Peak Min
 Max
To toggle between 100ms 
response time and 1ms response 
time under REC mode except 
resistance and capacitance range.
100ms
MAX
 MIN
100ms
MAX
 MIN
AVG
MAX/
MIN
REC 
Mode
Starts recording of maximum 
and minimum values. Steps the
display through the sequence of
present, high(MAX), low(MIN) 
and average(AVG) readings at 
any mode except at conductance 
mode. In 1ms response time, 
it steps through only MAX and
MIN reading.
Power-Up 
Option
To select 1 second high accuracy 
response time, press and hold
down MAX/MIN while turning
the rotary switch to any function 
setting.
RANGE
Manual
range
/auto-range
options
l Press RANGE to toggle 
between manual ranging 
and auto ranging mode at 
any rotary switch position.
Press RANGE to step 
through the ranges available 
for the selected function.
Press RANGE while turning on
the power to enter 80,000 counts 
resolution except at capacitance 
measurement.
Others
Functional Buttons(2)
Function
 LCD 
Symbol
HOLD
Data holding
Others
Press HOLD down to enter the 
Auto Hold mode at any mode.t
Press HOLD to switch between 
resistance and conductance value 
at conductance or resistance 
measuring mode. 
DATA 
HOLD
Selecting 
capacitance 
and DC/AC
l Press to select 
capacitance test at 
measurement position.
l Press to select AC/DC 
mode at current measurement 
position.
Power-Up 
Option
Press when turning on the 
Meter to disable Sleep Mode 
function.
nF F 
DCAC
REL 
Relative value 
measurement
Relative 
percentage 
value 
measurement 
Press REL to enter or exit 
mode at any rotary switch position.
Press REL to enter or exit % 
mode at any rotary switch position.
%
Hz
Frequency 
measurement
Press Hz once to enter frequency 
measurement in AC/DC voltage 
or current measurement positions.
Duty cycle 
measurement
Press Hz twice to enter duty cycle 
measurement in AC/DC voltage or 
current measurement positions.
Hz %
Display
Backlight
Press once to turn the Display 
Backlight on and it shall shut off 
automatically in around 60 
seconds later.
Measurement Ranges(1)
A measurement range determine the highest value the 
Meter can measure. Most Meter functions have more 
than one range. See "Accuracy Specifications".
A. Selecting a Measurement Range
Being in the right measurement range is important:
 If the range is too low for the input, the Meter displays 
  to indicate an overload.
 If the range is too high, the Meter will not display the 
 most accurate measurement.
B. Manual Ranging and Autoranging
The Meter has both manual range and autorange options:
 In the autorange mode, the Meter selects the best 
 range for the input detected. This allows you to 
 switch test points without having to reset the range.
 In the manual range mode, you select the range. 
 This allows you to override autorange and lock the 
 Meter in a specific range.
The Meter defaults to the autorange mode in measurement 
functions that have more than one range. When the Meter 
is in the autorange mode, is displayed.
To enter or exit the manual range mode:
1. Press RANGE.
 The Meter enters the manual range mode and 
 turns off.
 Each presses of RANGE increments the range. 
  When the highest range is reached, the Meter wraps 
 to the lowest range.
2. To exit the manual range mode, press and hold 
 RANGE for over 1 seconds.
 The Meter returns to the autorange mode and 
 is displayed.
Note
 In Hold, Max/Min mode, Press RANGE exits these 
 measurement modes and enters manual range mode.
 In Hz measurement mode, Press RANGE to 
  attenuate 10 times of input signal amplitude which 
  can increase the Meter sensitivity and stabilize the 
 correct reading.
 Press RANGE while turning on the power to enter 
  80,000 counts resolution except at capacitance 
 measurement.
Measurement Ranges(2)
When AC voltage measurement has been completed, 
disconnect the connection between the testing leads 
and the circuit under test, and remove the testing 
leads away from the input terminals of the Meter. 
Display Symbols(1) (see figure 2)
No.
Symbol
Meaning
8
6
4
3