User Manual

c)Frequency Sweep Mode
For linear frequency sweep, waveform generator changes output frequency in a linear way
during frequency sweep; for logarithmic frequency sweep, waveform generator changes
output frequency in a logarithmic way. Linear frequency sweep mode is default. To change
it, please press soft key Type Log on the interface for starting frequency sweep mode
(please press Return first to enter the interface for selecting frequency sweep waveform).
Figure 4- 35 Select logarithmic frequency sweep
d)Frequency Sweep Time
Set the time from starting frequency to stop frequency, which is 1s by default and in the
range of 1ms~500s. To change it, you can use multi-functional knob and direction key on
the interface for selecting frequency sweep mode or press soft function key
Param SweepTime , input number through numeric keyboard and press corresponding
soft key of unit.
Figure 4- 36 Set frequency sweep time
78