Product specifications
Automatic measurement of time parameters ascending edge to ascending edge;
Delay (descending edge): It refers to delay from
UTD2000/3000 series oscillograph can measure
descending edge to descending edge;
signal frequency, cycle, ascending time,
Positive duty cycle (+Duty): It refers to ratio of
descending time, positive pulse width, negative
positive pulse width and cycle;
pulse width, delay (of 9 combinations), positive
Negative duty cycle (-Duty): It refers to ratio of
duty cycle, negative duty cycle and 10 time
negative pulse width and cycle;
parameters automatically. Definitions of such
Measurement menu
time parameters are as follows:
Operation Description: Please press MEASURE key
RiseTime: It refers to period when waveform
so that the screen can display 5 measurement values.
amplitude increases from 10% to 90%;
As shown in Form 2-25, user can press any key of F1
FallTime: It refers to period when waveform
to F5 so that the screen enters into measurement
amplitude decreases from 90% to 10%;
selection menu.
Positive pulse width (+Width): It refers to pulse width
of positive pulse under 50% of amplitude;
Negative pulse width (-Width): It refers to pulse width
of negative pulse under 50% of amplitude;
Delay (ascending edge): It refers to delay from
Operating Manual for UTD2000/3000
63