Measurement Operation(10)
Model UT90C: OPERATING MANUAL
To measure current, do the following:
1. Turn off power to the circuit. Discharge all high-
voltage capacitors.
2. Insert the red test lead into theµAmA or 10A terminal
and the black test lead into the COM terminal.
Use the 10A terminal and A range if the current
value to be tested is an unknown.
3. Set the rotary switch to µA , mA orA .
4. The Meter defaults to DC current measurement mode.
To toggle between DC and AC current measurement
function, press SELECT button. AC current is
displayed as an mean value (calibrated against sine
wave effective value).
5. Break the current path to be tested. Connect the red
test lead to the more positive side of the break and
the black test lead to the more negative side of the
break.
6. Turn on power to the circuit.
The measured value shows on the display.
Note
l For safety sake, the measuring time for high current
should be less than 10 seconds for each measurement
and the interval time between 2 measurements
should be greater than 15 minutes.
l When current measurement has been completed,
disconnect the connection between the testing leads
and the circuit under test, and remove the testing
leads away from the input terminals of the Meter.