Specifications
info@tursdaletechnicalservices.co.uk
11
B. Digital Multimeter Mode
i.Measuring Voltages
Warning
To avoid harms to you or damages to the Meter from electric shock, please do not attempt to measure
voltages higher than DC 1000V, AC 750V, although readings may be obtained.
To measure voltages, set up the Meter as Figure 3-2 and do the following:
BlackRed
Figure 3-2. Voltages Measurement
1. Insert the red test lead into the V terminal and the black test lead into the COM terminal.
2. Set the rotary switch to V .
3. Connect test leads across with the object being measured.
4. The measured value shows on the display..
5. Press MODE button to toggle between Multimeter mode and Scope mode.
6. Press F1 to toggle between AC and DC voltage measurement.
When measuring voltage, the corresponding functional buttons
AC / DC REL Rang ▲ Rang ▼
F1 F2 F3 F4
F1: Toggle between AC or DC
F2: relative mode (REL will be displayed at the right bottom of the LCD when it is on)
F3: select a range up
F4: select a range down
Note:
z After changing the measurement mode, the autoranging will be off automatically and the AUTO will
be disappeared at the bottom left of the LCD.
z When voltage measurement has been completed, disconnect the connection between the testing
leads and the circuit under test and remove testing leads away from the input terminals of the Meter.