User Manual

10) AC Current
Frequency response
40Hz~1kHz
1kHz~10kHz
40Hz~1kHz
1kHz~10kHz
40Hz~1kHz
1kHz~10kHz
40Hz~1kHz
1kHz~10kHz
40Hz~1kHz
1kHz~10kHz
Accuracy
± (0.8%+10)
± (3%+50)
± (0.8%+10)
± (3%+50)
± (1.2%+10)
± (3%+50)
± (1.2%+10)
± (3%+50)
± (1.2%+10)
± (3%+50)
Resolution
0.01μA
0.1μA
1μA
10μA
1mA
Range
220μA
2200μA
22mA
220mA
20A
UT61E+
Range
UT61B+/UT61D+
600.0μA
6000μA
60.00mA
600.0mA
6.000A
10.00A (UT61B+)
20.00A (UT61D+)
Resolution
0.1μA
1μA
10μA
0.1mA
1mA
10mA
10mA
Accuracy
± (1.2%+5)
± (1.5%+5)
± (2.0%+5)
Display: True RMS
Frequency response: 40Hz~500Hz (UT61B+), 40Hz~1kHz (UT61D+),
40Hz~10kHz (UT61E+)
Accuracy guarantee (UT61B+/UT61D+): 5%~100% of 600.0μA range,
1%~100% of other ranges; open circuit allows least significant digit 5
Accuracy guarantee (UT61E+): 1%~100% of range at 40Hz~1kHz, 10%~100%
of range at 1kHz~10kHz (the minimum measured current at μA ranges is 3A);
open circuit allows least significant digit 10
The AC crest factor can be 3.0 at 3000 counts, and can only be 1.5 at
6000 counts. The additional error should be added according to the crest
factor of a non-sinusoidal wave as follows (UT61B+/UT61D+):
a) Add 4% when crest factor is 1~2
b) Add 5% when crest factor is 2~2.5
c) Add 7% when crest factor is 2.5~3
The AC crest factor can be 2.0 at 10000 counts, and can only be 1 at
22000 counts. The additional error should be added according to the crest
factor of a non-sinusoidal wave as follows (UT61E+):
a) Add 4% when crest factor is 1~2
b) Add 5% when crest factor is 2~2.5
c) Add 7% when crest factor is 2.5~3
Frequency measurement range: 40Hz~500Hz (UT61B+), 40Hz~1kHz (UT61D+),
40Hz~10kHz (UT61E+); input amplitude: 50% of current range.
Duty ratio is for reference only.
Frequency accuracy: ± (0.1%+4); resolution: 0.1Hz (UT61B+/UT61D+)
Overload protection: Same as that for DC current
11) Frequency/Duty Ratio
Range
10Hz~220MHZ
0.1%~99.9%
Resolution
0.01Hz~0.01MHz
0.1%
Accuracy
± (0.01%+5)
± (2%+5)
UT61E+
Range
10.00Hz~10.00MHZ
0.1%~99.9%
Resolution
0.01Hz~0.01MHz
0.1%
Accuracy
± (0.1%+4)
± (2.0%+5)
Frequency input amplitude:
100kHz: 200mVrms input amplitude 20Vrms
>100kHz~1MHz: 600mVrms input amplitude 20Vrms
>1MHz (UT61B+/UT61D+): 1Vrms input amplitude 20Vrms
>1MHz~40MHz (UT61E+): 1Vrms input amplitude 20Vrms
>40MHz (UT61E+): Not specified
Duty ratio measurement is only applicable to square waves.
1Vpp input amplitude 20Vpp
Frequency 10kHz, duty ratio: 10.0% ~ 90.0%
Overload protection: 1000V
UT61B+/UT61D+
33
34