Specifications
Accuracy Specifications (2)
C. Continuity, Diodes & Resistance Test
Range
Continuity Test
(340.0 )
Diode
340
3.4k
34k
340k
3.4M
34M
Resolution
0.1
1mV
0.1
1
10
100
1k
10k
Accuracy
Approximate
50
N/A
(1.2%+2)+sh
ort circuit
resistance
(1%+2)
(1.2%+2)
(1.5%+2)
Overload
Protection
600Vp
Remarks:
l Continuity Test 340.0 Range:
Buzzer beeps continuously.
Open circuit voltage approximate 1.2V.
l Diode Range:
Open circuit voltage approximate 2.8V.
Displays approximate forward current drop reading
1mA.
l 340 Range:
Open circuit voltage approximate 1.2V.
l 3.4k ~ 34M Range:
Open circuit voltage approximate 0.5V.
Model UT60D: OPERATING MANUAL
31