Accuracy Specifications (1)
Accuracy :± (a% reading + b digits), guarantee for 1 year.
Operating temperature : 23°C ±5°C.
Relative humidity : <75%.
Temperature coefficient : 0.1 x (specified accuracy)/1°C.
A. DC Voltage
Range Resolution Accuracy Overload Protection
400mV 0.1mV ±(0.8%+3)
1000V dc 750V ac rms
Continuous.
4V 1mV
±(0.8%+1)40V 10mV
400V 100mV
1000V 1V ±(1%+3)
Remarks: Input impedance
≥≥
10M
ΩΩ
.
B.AC Voltage
Range Resolution Accuracy Overload Protection
4V 1mV
±(1%+5)
1000V dc 750V ac rms
Continuous.
40V 10mV
400V 100mV
750V 1V ±(1.2%+5)
Remarks:
••
Input impedance
≥≥
10M
ΩΩ
.
••
UT60C displays effective value of sine wave (mean value response).
: displays true rms value.
••
Frequency response 40Hz to 400Hz.
C. Resistance
Range Resolution Accuracy Overload Protection
400Ω 0.1Ω
Measure at
REL mode
±(1.2% + 2)
1000Vp
4kΩ 1Ω
±(1% + 2)
40kΩ 10Ω
400kΩ 100Ω
4MΩ 1kΩ
±(1.2% + 2)
40MΩ 10kΩ
±(1.5% + 2)
Remarks: Open circuit voltage approximate 0.45V.