Model UT50D: OPERATING MANUAL
l Maximum voltage
between any Terminals
and Grounding :1000V rms.
l
Fused Protection
for mA Input Terminal :0.5A, 250V fast type,
5x20mm.
l
Fused Protection
for 20A Input Terminal :Un-fused.
l Range :Manual ranging.
l Maximum Display :1999.
l Mesaurement Speed :Updates 2~3 times/second.
l Temperature:
Operating:0
o
C~40
o
C(32
o
F~104
o
F)
Storage: -10
o
C~50
o
C(14
o
F~122
o
F).
l Relative Humidity : 75% @ 0
o
C~30
o
C;
50%@31
o
C~40
o
C.
l Altitude: Operating :2000m; Storage: 10000m.
l Battery Type :9V NEDA1604 or 6F22 or
006P.
l Battery Deficiency :Display “ ”.
l Data Holding :Display “ H
l Negative reading :Display “
l Overloading :Display “1”.
l Dimensions (HxWxL) :165x80x38.3mm.
l Weight : Approx.275g (battery
included).
l Safety/Compliances :IEC61010 CAT II 1000V,
CAT III 600V overvoltage
and double insulation
standard.
l Certificate: