Specifications

10 11
Contact Inputs (/EX)
PID Control AT
Alarm & Timer
Outputs
(/AL)
AL2AL1
Rate-of-change
Limiter
SP2SP1
Manual
SP selection
STOP/RUN Switching
Timer ON
signal
AUTO/MAN
DI1
DI2
Bias & Filtering
PV Input
Relay Contact Outputs
Reverse MV
Direct MV
Estimated
valve position
Pre-set Output
Functions Selector
Comparator
4848(1/16DIN)Controllers
Lit when SP is
being displayed.
Lit when SP2 is
being used for
operation.
Lit when alarm
occurs.
Lit while control
output is
being output.
Lit when the segment no.
or remaining segment
time is displayed on
SP display.
EV1: Lit when event 1
is activated.
EV2: Lit when event 2
is activated.
Lit while the operation
mode is “HOLD”.
Lit while the operation
mode is “RUN”.
PV/SP Data display
PV Input
Indication accuracy
Control scan period
Control loops and mode
Number of Setpoint (SP)
Number of Program patterns/segments
Control Algorithm
SUPER, Auto tuning
Control Outputs
PV Retransmission Output
Timer function
Program time span
Digital Inputs
Digital Outputs
RS485 Communication Protocols
Approvals
Other specifications
Ambient T, Limits RH
500ms
1 loop, AUTO mode only
1 loop, RUN/RESET, HOLD/Cancel HOLD
SUPER
NA
0 second to 1,599 hour
2 (RUN/RESET, HOLD/Cancel HOLD)
2 (PV event and Time event)
Two-wire, MODBUS, PC-link, Ladder
General = UL, CE, CSA Front Protection= IP65
Size=48*48*100mm, Power supply = 24VAC/DC or 90 to 264V AC, Power consumption=8VA
0 to 50 , 20 to 90%
UT130/150 and UP150 Specification Table
UT130
3 digits
1 universal input (TCs, RTDs)
2
˚C
1digit for TC
1
˚C
1digit for RTD
UP150UT150
4 digits / 4 digits
1 universal input (TCs, RTDs, mV, V)
2
˚C 1digit for TC
1
˚C 1digit for RTD
0.3%1digit for mV/V input
1
ON/OFF, Time-proportional PID,
Heating & Cooling
2
ON/OFF, Time-proportional PID,
Continuous PID, Heating & Cooling
NA
1 program pattern/16 segments
ON/OFF, Time-proportional PID,
Continuous PID
NA
SUPER, Dynamic AT
Select from Relay or Voltage Pulse
Not available (NA)
NA
NA
Two timers (0 to 99min.59sec)
2 (sp1/sp2, RUN/STOP, Timer function)
Select from Relay, Voltage Pulse or 4 to 20mA
1 point (4 to 20mA)
NA
2 (Alarm or Timer outputs)
Model Suffix Code
Notes
Description
Temperature controller
Relay contact output (for time-proportional PID or on/off control)
Voltage pulse output (for time-proportional PID)
Power Supply 24VDC/24VAC
Communication function Note 2
/V24
Power Supply 24VDC/24VAC
/V24
No cooling output (Standard type)
Relay contact output (for time-proportional PID)
Voltage pulse output (for time-proportional PID)
Alarm outputs (2 points) Note 1
Heater burnout alarm and 2 other alarm outputs
(includes the functions of /AL) Notes 1, 2, 3
-R
-  
-V
N
R
V
/AL
/HBA
/RS
UT130
Output signal
(for heating) Note 1
Output signal
for cooling
Options
"/AL" cannot be specified when specifying "/HBA" .
"/HBA" and "/RS" cannot be specified at the same time when
selecting heating/cooling type.
Sensor of heater burnout alarm is CTL-6-S or CTL-12-S36-8
(URD Co., Ltd., Japan) To be purchased separately
Note 1:
Note 2:
Note 3:
-  
Model
Suffix Code
Description
Temperature controller
Relay contact output(for time-proportional PID or on/off control)
Voltage pulse output (for time-proportional PID)
4 to 20 mA output (for continuous PID) Note1
No cooling output (Standard type)
Relay contact output (for time-proportional PID control)
Voltage pulse output (for time-proportional PID)
4 to 20 mA output (for continuous PID)
4 to 20 mA retransmission output of measured value (PV) Notes 3, 5
Switchover between SP1 and SP2, and starting of timer
by external contacts Notes 4, 6
Heater burnout alarm and 2 other alarm outputs
(includes the functions of /AL) Notes 1, 2, 3, 6, 7
Alarm outputs (2 points) Note 2
-R
-V
-A
N
R
V
A
Communication function Notes 4, 6
/EX
/HBA
/AL
UT150
Output signal
(for heating) Note 1
Output signal
for cooling
Options
Notes
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
"/HBA" can not be specified when selecting."-A:4 to 20mA
output".
"/AL" can not be specified when "/HBA" is specified.
"/HBA" and "/RET" cannot be specified at the same time
when selecting standard type.
"/EX" and "/RS" cannot be specified at the same time when
selecting standard type.
"/RET" cannot be specified when selecting heating/cooling
type.
"/HBA","/EX" and "/RS" cannot be specified at the same time
when selecting heating / cooling type.
Sensor of heater burnout alarm is CTL-6-S or CTL-12-S36-8
(URD Co., Ltd., Japan) To be purchased separately
/RET
/RS
Power Supply 24VDC/24VAC
/V24
-  
Model
Suffix Code
Description
Program Temperature controller
Relay contact output(for time-proportional PID or on/off control)
Voltage pulse output (for time-proportional PID)
4 to 20 mA output (for continuous PID)
Always N
4 to 20 mA retransmission output of measured value (PV)
Two digital inputs for RUN/RESET and HOLD/CANCEL Note 1
-R
-V
-A
N
Communication function Notes 1
/EX
UP150
Output signal
Options
Fixed code
Notes
Note 1: /RS option and /EX option cannot be specified at the same
time.
/RET
/RS
Model and Suffix Codes
When specifying the /RS option, be sure to order the required number of copies of Communication Functions User's Manual separeately.
UT150 Function Block Diagram
Functional block diagram for Heating & Cooling type UT150 controller.
Contact Inputs (/EX)
DI1
SUPER & AT
PV & Time
Events
PV Output
EV2
EV1
Relay contact,
Voltage Puse or 4 - 20mA
DI2
Run/
Reset
switching
PV Input
4 to 20mA
PV Retransmission
Output (/RET)
Output
Program Setpoint
Hold/
Re-start
switching
Bias & Filtering
PID Control
RUN
Bias & Filtering
Contact Inputs (/EX)
DI1
PID Control
SUPER &
Dynamic AT
Heater Current
Detection Input (/HBA)
For Heater
Disconnection
Alarm
Alarm & Timer
Outputs
(/AL or /HBA)
PV Output
Relay contact, Voltage Puse or 4 - 20mA
for each output
Functions Selector
Rate-of-change
Limiter
SP2SP1
DI2
SP selection
STOP/RUN
switching
Timer ON
signal
STOP
PV Input
4 to 20mA
PV Retransmission
Output (/RET)
Heating Output
Cooling Output
Pre-set Output
CT
AL2AL1
SUPER Function & Dynamic AT
UP150 Function Block Diagram
Temperature Program
SUPER control function suppresses
overshooting. The field-proven SUPER
function utilizes build-in operator experi-
ence and Fuzzy theory to deliver fine
cotrol and suppress overshooting.
Number of program pattern: One
Accuracy of program time span: +/-2% of span
Program operations: Wait, Hold, Advance
Conventional PID control
UT100 control with SUPER
Time
Temperature
The Dynamic Auto Tune function of the
UT130 and UT150 series assures
stabel control. Whenever you change
the setpoint(SP), the function automati-
cally turns the PID parameters and
updates them to the suitable setting.
Start Max. 1,599 hours
Time Event Output
Up to 16 segments
Dynamic AT is started
when SP is changed.
PV
SP
Time
Temperature
UT150 /Z Motorized Valve Controller
Model UT150/Z has two relay contact outputs to control a motor-
ized valve or a motorized actuator. Model UT150/Z does not need
the valve position feedback signal. This controller estimates the
valve position automatically.
UT150/Z has MAN mode for moving the valve position manually.
Non-linear control function is available to prolong the valve life.
Alarms
Outputs
Motorized
Valve
UT150/Z