Contents Il. Open-case inspection: 1ll. Safety operation guidelines—IV. Electrical symbol—a V. Textual VL. Display VII. Key function, auto power-off and buzzer—8 VIII. Technical 9 IX. Measurement operating 1. AC measurement 2. DC current measurement— —17 3.AC voltage measurement 4. DC voltage measurement 5. Resistance measurement 6. Continuity 7. Diode measurement 8. Capacitance measurement —26 9. Frequency 10. Temperature measurement 11. Non-contact AC voltage sensing NEV-30 12. Power gear 13.
1. Overview UT216A/B/C is a portable true 35/6 bit (6000 Counts), auto range clamp am ‘with simulation bar. The clamp ammeter, cantered by large scale integrated circuit Z/A analog-gallant converter, featuring functional on screen display, full-rare overload protection and unique appearance design has become a specific clamp ammeter with superior performance.
phenomenon. If any abnormal condition were found: bars test pen, damaged chassis Insulation, no display In LCD, or the clamp meter Is thought not be able to work normally, please do not use it. 2.1t is forbidden to use the clamp ammeter prior to having rear cap and battery cover in place, or otherwise there will be electric shocking. 3.
V. External construction (See Figure 1) 1.Clamp head: A device used to measure AC/ DC current and caver current Into voltage. 2.Clamp body:Safety design to protect operator from touching the dangerous area. 3.Clamp head pulling handle:Press the trigger to open the clamp head, when release the trigger, clamp head will partially closed. 4.Dial switch: Select the measurement function gear. 5.Function key: Select basic functions. 6.LCD display area: Display the measured data and functional symbols. 7.
High voltage prompt Battery low voltage prompt Relative value prompt Auto shutdown prompt Data hold prompt Unit prompt DC signal prompt AG signal prompt oo[ula[alalwen]= Diode prompt 10 Circuit on-off measurement prompt 11 Auto range prompt 12 Simulation bar prompt 13 measurement prompt 14 Non-contact AC voltage sensing prompt 15 Frequency conversion measurement prompt| 16 Temperature unit prompt 7 VII Key functions 1.SELECT It ls able to select gear by a short press.
and capacitance measurement. Press again to exit relative value measurement mode. Under DC current gear measurement mode, short press to enter clearing mode, LCD will display “ A ", press again to exit clearing mode. When UT216B is at AC voltage gear, long press this key to enter voltage frequency measurement. Long press it again to exit voltage frequency measurement.
11.NCV Range Accuracy 2100Vms; <10mm Nev (LED/Buzzer indication) IX. Instructions for measurement operation 1.AC measurement {see Figure 4) 1) Push the switch to AC current gear , press trigger to open the clamp head to take the conductor to be measured, then slowly loosen the trigger until clamp head is completely dosed.
Figure 5 2. DC current measurement (UT216C only) {See Figures 5) 1)Push the switch to DC current gear , when LCD display is not zero, press REL to clear. After measuring blg current gear, clamp head will be left with permanence, and LCD display will have base values. 2)Press trigger to open the clamp head to take the conductor to be measured, then slowly loosen the rigger until clamp head Is completely dosed.
3. AC voltage measurement (ses Figure 6) 1) Insert red test pen In “v" Jack and black test pen In "COM" Jack. 2)Push the function range switch to the DC voltage measurement gear , and connect test pen in parallel with the power or load to be measured. 3)Read true value of AC voltage from the display. 4)Long press SELECT key at AC voltage gear to select VFC measurement, measure frequency converter voltage.
4. DC voltage measurement (See Figure 7} 1) Insert red test pen in “v” jack and black test pen In “COM” Jack. 2) Push the function range switch to the DC voltage measurement gear , and connect test pen in parallel with the power or load to be measured. 3) Directly read the measured resistance value from display. Note: @ Do not input voltage higher than 1000V. It may be feasible to measure higher voltage, but damage will be caused to the meter.
® Before measuring resistance on-line, the power of circuits being measured shall be powered off and all capacitors shall release out residues of electric charges to assure the measurement accuracy. Figure 8 6. Continuity test (see Figure 9) 1) Insert red test pen in “0" jack and black test pen in "COM" jack. 2)Push the function range switch to the measurement gear press SELECT to select circuit on-off measurement -4 and connect test pen in parallel with the two terminals of measured circuit.
7. Lode measurement (See Figure 10) 1) Insert red test pen in “Q" jack and black test pen in “COM" jack. Polarity of red and black test pen is respectively and 2) Push the function range switch to the measurement gear press SELECT to select diode measurement »+ and directly read out the approximate forward direction PN junction voltage. For silicon PN junction, generally 500~800mV is confirmed to be the normal value.
Note: @ If the measured capacitance is short circuited or capacitance exceeds the maximum range of the meter, display will show capacitance measurement mode, simulation bar indicator is forbidden. It will take longer time to achieve the correct reading when measuring capacitance larger than 600uF.
10. Temperature measurement (UT216C only) (see Figure 1 3) 1) Push range switch fo "C "F” gear, LCD will display OL, the short-circuit test pen displays the room temperature. 2) Insert temperature K type socket in the corresponding hole as per the diagram. 3) Put temperature robe detect the measured surface, several seconds later, directly read out the measured Celsius temperature value from LCD. 4} Press SELECT to select Fahrenheit temperature measurement.
12. Power gear{OFF) Instrument should ba powered off. 13. Automatic shutdown function If not turning knob switch or pressing key to the clamp ammeter within the user-defined shutdown time (default 15min), display will be bank and enter the low power consumption dormant state. If need to wake up meter, press key to wake up meter. Crass SELECT key to start up machine. Automatic shutdown function is forbidden. X.