User Manual

Table Of Contents
UT108/109 OPERATING MANUAL
20
Measurement Operation
Part 1 Multimeter Basic Testing
A. AC/DC Voltage Testing (see gure 4)
Warning
To avoid harms to you or damages to the Meter from electric shock, please do
not attempt to measure voltages higher than 1000Vp although readings may be
obtained.
Please take extra care when measuring high voltages to avoid electric shock.
To measure DC voltage, connect the Meter as follows:
1. Insert the red test lead into the V terminal and the black test lead into the COM terminal.
2. Set the rotary switch to an appropriate measurement position in V , press BLUE
button to switch between AC and DC measurement mode.
3. AC voltage measurement display true rms value and press Hz button to obtain the
frequency value, input amplitude and frequency response refer to accuracy
specications.
4. Connect the test leads across with the object being measured.
The measured value shows on the display.