Instruction manual

23
WARNING:
Disconnect the Electrode Holder cable from the machine before using MIG function. If cable is not disconnected welding
voltage is present and can cause arcing or ash.
Installation set up of the Spool Gun with UNI-MIG-MIG210/250 DIGITAL MTS
(1) Connect the spool gun control cable and gun cable connector.
IMPORTANT : When connecting the torch be sure to tighten the connection.
(2) Connect the earth lead to
(3) Select the SPOOL GUN function with the Tig/MMA/MIG/SPOOL GUN selector switch.
(4) Set torch operation 2T / 4T.
When 2T operation is selected press trigger Arc starts, release trigger Arc stops.
When 2T operation is selected with downslope time of either 2 or 3 seconds press trigger Arc starts,
release trigger, after 2 or 3 seconds depending on the downslope time selected Arc stops. Crater ll
operation is automatic and preset.
When 4T operation is selected press and release trigger Arc starts, press and release trigger Arc stops.
When 4T operation is selected with downslope time of either 2 or 3 seconds press and release trigger
Arc starts. Press and hold trigger, after 2 or 3 seconds depending on the downslope time selected
Arc crater ll downslopes to factory preset level, release trigger Arc stops.
NOTE: This feature is recommend for welding above 120Amps only.
(5) If required select downslope time for crater ll
(6) Select post gas ow time.
(7) Adjust inductance control, Hard or Soft Arc
(8) Connect Gas Line to Gas Regulator and connect the gas regulator to the Gas Cylinder.
(11) Place a spool of wire onto the Spool
holder. Note: the spool retaining nut is Left
Hand thread, turn it clockwise to undo it
(10) Push the cover release button to
unlock the wire feed /spool cover
Note: Pictures may vary from your model machine
(4) SetTorchoperation2T/4T
(1) Connect Spool Gun control
cableandguncableconnector
(8) Connect the gas line to the regulator
and connect to the gas cylinder
(3)SetTig/MMA/Mig/SpoolGun
selector
switch to Spool Gun
IMPORTANT : When connecting the torch
besuretotightentheconnection.
( 2) Connect earth lead to
(5) If required select downslope time for
crater fill
(6) Select Post gas flow time.
(7) Select Inductance control.
(9) Connect weld power lead to GAS
WARNING:
Ensure that an approved welding helmet, protective clothing and gloves are use for all welding operations