Instruction manual
14
Installation set up for MIG with Gas for UNI-MIG-MIG210/250 DIGITAL MTS
(1) Connect Mig Torch
IMPORTANT : When connecting the torch be sure to tighten the connection. Additionally Digital MIG
torch must be connected prior to power being turned on otherwise remote control will not work
(2) Connect the earth lead to
(3) Select the MIG function with the Tig/MMA/MIG/SPOOL GUN selector switch.
(4) Set torch operation 2T / 4T.
• When 2T operation is selected press trigger Arc starts, release trigger Arc stops.
• When 2T operation is selected with downslope time of either 2 or 3 seconds press trigger Arc starts,
release trigger, after 2 or 3 seconds depending on the downslope time selected Arc stops. Crater ll
operation is automatic and preset.
• When 4T operation is selected press and release trigger Arc starts, press and release trigger Arc stops.
• When 4T operation is selected with downslope time of either 2 or 3 seconds press and release trigger
Arc starts. Press and hold trigger, after 2 or 3 seconds depending on the downslope time selected
Arc crater ll downslopes to factory preset level, release trigger Arc stops
NOTE: This feature is recommend for welding above 120Amps only.
(5) If required select downslope time for crater ll
(6) Select post gas ow time.
(7) Adjust inductance control, Hard or Soft Arc
(8) Connect Gas Line to Gas Regulator and connect the gas regulator to the Gas Cylinder.
WARNING:
Disconnect the Electrode Holder cable from the machine before using MIG function. If cable is not disconnected welding
voltage is present and can cause arcing or ash.
(10) Place wire onto spool holder - (spool
retaining nut is left hand thread ) Feed the wire
through the inlet guide tube on to the drive
roller.
(9) Connect weld power lead to GAS
(11) Feed wire over the drive roller into the
outlet guide tube, Push the wire through approx
150mm.
(4) SetTorchoperation2T/4T
(1) Connect Mig torch
(8) Connect the gas line to the regulator
and connect to the gas cylinder
(3)SetTig/MMA/Mig/SpoolGun
selector
switch to Mig
IMPORTANT : When connecting the torch
besuretotightentheconnection.
AdditionallyDigitalMIGtorchmustbe
conectedproirtopowerbeingturnedon
otherwiseremotecontrolwillnotwork
( 2) Connect earth lead to
Note: Pictures may vary from your model machine
(5) If required select downslope time for
crater fill
(6) Select Post gas flow time.
(7) Select Inductance control.
WARNING:
Ensure that an approved welding helmet, protective clothing and gloves are use for all welding operations










