Installation Guide
8
 ■ A 120-volt, 60 Hz., AC-only, 15-amp, fused electrical circuit 
is required.
 ■ If the house has aluminum wiring, follow the procedure 
below:
1.  Connect a section of solid copper wire to the pigtail 
leads.
2.  Connect the aluminum wiring to the added section 
of copper wire using special connectors and/or tools 
designed and UL Listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
 ■ Wire sizes and connections must conform with the rating of 
the appliance as specified on the model/serial/rating plate. 
The model/serial/rating plate is located inside the range hood 
on the left wall.
 ■ Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.
INSTALLATION INSTRUCTIONS
Prepare Location
NOTE: It is recommended that the vent system be installed 
before hood is installed.
Before making cutouts, make sure there is proper clearance 
within the ceiling or wall for exhaust vent.
1.  Disconnect "wer.
2.  Depending on your model, determine which venting method 
to use: roof, wall, or non-vented (recirculating).
3.  Select a flat surface for assembling the range hood. Place 
covering over that surface.
4.  Lift the range hood and set it upside down onto covered 
surface.
Determine Wiring Hole Location
Cut only one 1¹⁄
4
" (3.2 cm) diameter wiring access hole.
1.  Determine and clearly mark a vertical centerline on the wall 
and cabinet in the area the vent opening will be made.
A. Centerline
To wire through top:
1.  Mark a line distance “A” from the right of the centerline 
on the underside of the cabinet. For 12" (30.5 cm) deep 
cabinets, mark the "int on this line that is 2" (5.1 cm) from the 
back wall. For 15" (38.1 cm) deep cabinets, mark the point 
on this line that is 5" (12.7 cm) from the back wall. Drill a 1¼" 
(3.2 cm) diameter hole through the cabinet at this "int.
To wire through wall:
1.  Mark a line distance “A” from the right of the centerline on 
the underside of the wall. Mark the point on this line that is 
7
⁄
8
" (2.2 cm) from the underside of the cabinet. Drill a 1¹⁄
4
" 
(3.2 cm) diameter hole through the rear wall at this "int.
A. 8³⁄
8
" (21.3 cm)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
A
Centerline
⁷⁄₈" (2.2 cm
)
Centerline
A
B
A. 8³⁄
8
" (21.3 cm)
B.  2" (5.1 cm) for 12" (30.5 cm) deep cabinets*
  5" (12.7 cm) for 15" (38.1 cm) deep cabinets*
  *From wall, not cabinet frame