Owner's Manual WS-165-164 Everyday Series Water Softener
Table of Contents 2 WHAT'S INCLUDED 3 OPERATING CONDITIONS 4 ASSEMBLY INSTRUCTIONS 6 FLUSHING THE WATER LINES 13 MASTER PROGRAMMING 14 PROGRAMMING KEYAND GENERAL INFORMATION 19
What is included with the WS-165-164 Check the entire unit for any shipping-related damage, missing parts, or damage to shipping cartons. Inspect the mineral tank and the brine tank closely, inspect by look and feel. Shipping-related damage can be small and difficult to detect. Contact the transportation company for all damage and loss claims. Tier1® is not responsible for damages in transit.
Operating Conditions This softening system will operate at maximum efficiency when the following conditions are considered: Operating Conditions: Working Conditions Working Environment Inlet Water Quality Working pressure 21psi to 120psi Water temperature Environment temperature Relative humidity 40 °F - 120 °F (5°C - 50°C) Power source AC100~240V/50~60Hz Water turbidity Down-flow Regeneration < 5FTU Chlorine < 0.1ppm Iron2+ < 0.
ASSEMBLY INSTRUCTIONS Locate the following parts: Brine Tank – inside the brine tank you will find: A. B. C. D. E. F. G. H. I. Bypass Valve Control Valve Clear Drain Tubing (10') PVC Tubing Upper Distributor Brine Valve Brine Well Pipe Fitting Connectors (x2) Control Valve Power Cord H. Parts Bag includes: 1. 2. 3. 4. 5. 6. Master O-ring (3.
PRIOR TO ASSEMBLY IMPORTANT NOTE: To avoid irreversible damage to connector threading, hand tighten plastic connections first. If leaks are noted during initial start up, gently tighten with tool. A. Prior to installation of this water softener, ensure you are aware of local laws and codes regarding the installation, use, and maintenance of water softeners. B. Resin Tank - the tank may be shipped with a temporary shipping cap, a master O-Ring, and a piece of tape covering the riser tube.
ASSEMBLY INSTRUCTIONS STEP 1: Attach the Control Valve to the Resin Tank A. Locate the Master O-ring (from Parts Bag) and lightly coat with silicone lubricant (from Owner’s Manual Zip-Lock Bag). Insert into bottom of control valve, as shown below. B. Connect the upper distributor, to bottom of control valve, line up slots and twist, as shown below. C. Center the riser pipe within the resin tank. D. Attach the control valve to the resin tank by sliding the upper distributor over the riser pipe. E.
ASSEMBLY INSTRUCTIONS E. Insert the connectors into the pipe fittings. The outlet connector containing water meter probe dock and the impeller must be installed in the outlet side of the bypass valve (as marked). Insert water meter probe in dock. F. Reinstall the plastic clamps on the connectors. Proceed to Step 4 Step 3: Assembly using the included bypass valve A. Insert blue washers (from Parts Bag) into input and output connections on the control valve, as shown below. B.
ASSEMBLY INSTRUCTIONS D. To attach the bypass valve onto the control valve, remove plastic clamps from both inlet and outlet of bypass valve. Remove pipe fitting ends from bypass outlets and thread onto control valve. Connect bypass valve onto fittings and reinstall plastic clamps. E. Insert water meter probe from control valve into the bypass valve’s on-board water meter probe dock, ensuring it is securely seated, as shown below. Step 4: Connect the brine line to the brine tank A.
ASSEMBLY INSTRUCTIONS Figure 1.1 B. Unscrew connecting nut(1) from brine valve (2) attached to brine tubing, as shown in Figure 1.1. C. Verify the plastic sleeve is inserted completely into the end of the brine tube as shown below. D. If necessary, adjust position of connecting nut on brine tubing to allow threads to engage completely with brine valve. 10 E. While pushing brine valve threads through hole in brine well, push brine tubing with connecting nut firmly into brine valve. F.
ASSEMBLY INSTRUCTIONS J. Insert the red brine line flow control (from Parts Bag) with the cone side facing into control valve, into the control valve brine line connector. K. Insert brine line into control valve. Tighten the nut onto the brine line connection, as shown in the area of magnification below.
ASSEMBLY INSTRUCTIONS C. Secure the clear drain tubing over a floor drain or other suitable drain. Check your local codes to ensure compliance. STEP 6: Connect the backwash hose to the control valve A. Insert washer (from Parts bag) into ribbed drain connector. B. C. D. E. Thread ribbed drain connector (from Parts Bag), onto drain connection. Attach clear drain tubing to connector. Secure using a hose clamp (from Owner’s Manual Zip-Lock bag).
FLUSHING THE WATERLINES Before operating water softener for the first time, flush out your water lines and the water softener bypass. • Check that bypass is closed. Knob on top of inlet should be turned to "By-Pass" (side opposite of "In-Serv") • Turn the water source on at the inlet to your home. • Disconnect the bypass from the control valve by removing plastic clamps and pulling bypass out of fitting. • Remove the meter impeller from the bypass by tilting bypass downward until it drops out.
MASTER PROGRAMMING Valve Programming Instructions and ∗ When LED is on press and hold both ∗ To program the valve, press ∗ To navigate to each programming stage, press ∗ To adjust that programming stage value, press ∗ To exit the programming, press and the buttons simultaneously for 3 seconds to unlock. will turn on. This indicates you are in the programming mode. or and use the to adjust the values. Follow the steps on next pages. to return to service status.
FACTORY DEFAULT SETTINGS Function Indicator Factory Default Parameter Set Range Time of Day Random 00:00~23:59 A-01 Control Mode A-01 A-01 A-02 Unit Mode HU-02 HU-02 01, 02, 03 Regeneration Time 02:00 02:00 00:00~23:59 Instruction Set the current time of day while the “:” flashes. Meter Delayed. Regeneration occurs at the set regeneration time once the gallons used reaches zero (0). Meter Immediate. Regeneration occurs immediately once the gallons used reaches zero (0).
MASTER PROGRAMMING Step by Step Programming Instructions Items Process steps Screen Display Note: when “12:12” flashes; Time of Day needs to be reset. 1. Press Time of Day Control Mode Unit Mode Regeneration Time Water Treatment Capacity Backwash Time Brine & Slow Rinse Time to set Time of Day; both and will light and the “:” symbol will flash. 2. Press , both and “H" value will flash, press or to adjust hour value. 3.
MASTER PROGRAMMING Step by Step Programming Instructions Continued Fast Rinse Time Maximum Regeneration Days Signal Output Mode 1. Press to enter FastRinse Time, 2. Press or 3. Press to accept adjustments made. Press 1. Press to enter Maximum Interval Regeneration Days, 2. Press or 3. Press to accept adjustments made. Press 1. Press to enter Signal Output Mode, and “b-01” value will flash. or 2. Press to adjust the signal output mode value. 3. Press to accept adjustments made.
CARE AND MAINTENANCE BRIDGING Humidity or the wrong type of salt may create a cavity between the water and the salt. This action, known as “bridging”, prevents the brine solution from being made, preventing the water softener from working. If you suspect salt bridging, carefully pound on the outside of the plastic brine tank, or pour some warm water over the salt to break up the bridge.
PROGRAMMING KEY AND GENERAL INFORMATION * Programming Key Time of Day Indicator LED on, displays the time of day. LED flashes, need to reset time of day after electrical service has been interrupted for 3 days or more. Button Lock Indicator LED on, indicates the buttons are locked. buttons for 3 seconds until the *To unlock, press and hold both and LED turns off. Program Mode Indicator LED on, enter program display mode. Use or buttons to view all values. ∗ LED flashes, enter program set mode.
WS-165-164 Series Water Softener Tier1® Tier1® is a registered trademark of US Water Filters, Inc., Zumbrota, Minnesota Copyright© 2019 US Water Filters, Inc. All rights reserved. www.Tier1water.