Instructions / Assembly

Operating Conditions:
Working Conditions
Working pressure 21psi to 120psi
Water temperature
40 °F - 120 °F (5°C - 50°C)
Working Environment
Environment
temperature
40 °F - 120 °F (5°C - 50°C)
Relative humidity
≤ 95% When temperature is 25°C/77°F
Power source AC100
240V/50
60Hz
Inlet Water Quality
Water turbidity Down-flow Regeneration < 5FTU
Water hardness 1 grain per gallon (gpg) = 17.1 parts per million (ppm)
Chlorine
< 0.1ppm
Iron
2+
< 0.3ppm
Operating Conditions
This softening system will operate at maximum efficiency when the following conditions are considered:
4
All plumbing and electrical work should be performed by an accredited professional to ensure all local, state, and
municipal guidelines are met.
Do not use the control valve with water that is unsafe or of unknown quality.
Do not use the brine tube, injector body, or other connectors on the valve as a handle to carry the system.
Ensure there is salt in the brine tank at all times when in use for softening. The brine tank should contain clean
water softening salt only, at least 99.5% pure. Do not use small grain salt.
When there is moderate to high turbidity, a filter should be installed before the softening system on the inlet side.
If the water pressure exceeds 80 psi, it is recommended to install a pressure valve. If the water pressure is under 20
psi, a booster pump must be installed before the water inlet.