Installation Guide

ASSEMBLY INSTRUCTIONS
E.
Insert the connectors into the pipe fittings. The outlet connector containing water meter probe dock
and the impeller must be installed in the outlet side of the bypass valve (as marked).
F.
Reinstall the plastic clamps on the connectors.
Proceed to Step 4
Step 3: Assembly using the included bypass valve
A.
Insert blue washers (from Parts Bag B) into input and output connections on the control valve,
as shown below.
B.
IMPORTANT: If you are using the bypass valve, the meter impeller must be installed for the
bypass valve to function properly. Locate pipe fitting connectors (inside control valve box). The
outlet connector with water meter probe dock (as shown) contains the meter impeller. Remove the plastic
clamp from the outside of the outlet connector, and pull apart the connector to access the impeller inside.
Remove the meter impeller. Note: You will not need the connectors for your installation and may discard
them.
C.
Remove the plastic clamp from the bypass valve outlet side. Pull out the pipe fitting. Insert the
meter impeller into the bypass valve, fan blade side facing down, rotating the meter impeller to
ensure the grooves of the meter impeller frame align with the grooves inside of the bypass valve
outlet as shown below. Replace pipe fitting into bypass valve. Replace plastic clamp.
8