Installation Guide
PROGRAMMING KEY AND GENERAL INFORMATION
*
19
Programming Key
Time of Day Indicator
LED on, displays the time of day.
LED flashes, need to reset time of day after electrical service has been interrupted for 3 days or more.
Button Lock Indicator
LED on, indicates the buttons are locked.
* To unlock, press and hold both and
buttons for 3 seconds until the
Program Mode Indicator
LED turns off.
∗
LED on, enter program display mode. Use or buttons to view all values.
∗
LED flashes, enter program set mode. Press
or
buttons to adjust values.
Menu/Confirm Button
*
Press
,
the
LED turns on; enter program display mode, press
or
to view all values.
*
In program display mode, press the
*
Press after all program features are set.
Manual /Return Button
LED flashes; enter program set mode and press
or
to adjust values.
*
Press the button to proceed to the next step. (Ex: Press the
button while the valve is in Service
status and it will start a manual regeneration. Press again and the valve will go to Brine & Slow Rinse instantly.)
*
Press the
*
Press the
*
Press the
button in program display mode and it will return to In Service.
button in program set mode and i t will return to program display mode.
while adjusting the value and it will return to program display mode directly without saving value.
*
Press and hold both and
simultaneously for 3 seconds to unlock the program functions.
to adjust values.
*
In program display mode press
or to view all values.
Down and Up Buttons
* A flashing dynamic display stripe indicates the water softener is in service.
A steady dynamic display stripe indicates the water softener is in the regeneration cycle
*
In program set mode press or