Installation Guide
FACTORY DEFAULT SETTINGS
Function
Indicator
Factory Default
Parameter Set
Range
Instruction
Time of Day
Random
00:00
~
23:59
Set the current time of day while the “:” flashes.
Control Mode A-01 A-01
A-01
Meter Delayed. Regeneration occurs at the set regeneration time
once the gallons used reaches zero (0).
A-02
Meter Immediate. Regeneration occurs immediately once the
gallons used reaches zero (0).
Unit Mode
HU-02 HU-02 01, 02, 03 01-m
3
; 02-gal; 03-L
Regeneration Time
02:00 02:00
00:00
~
23:59
Regeneration time. “:” light on
Water Treatment
Capacity
2500 0-10,000
To figure capacity, multiply the total resin volume multiplied
by .75. Divide by grains of hardness of water supply.
Example: 2 Cu/Ft = 64000 x .75 at 15 grains hardness.
(64000 x .75) ÷ 15= 3200 gallons.
Backwash Time
10 min.
0
~
99
∶
59
Backwash Time.
Brine & Slow Rinse
Time
60 min.
0
~
99
∶
59
Brine & Slow Rinse Time.
Brine Refill Time 10 min.
0
~
99
∶
59
Refill Time is calculated based on total resin volume. Note: 1
gal water dissolves 3lbs of salt.
Fast Rinse Time
10 min.
0
~
99
∶
59
Fast Rinse Time.
Maximum Interval
Regeneration Days
H-30 30
0
~
40
Forced regeneration every 30 days if no water has been used.
Time Clock Valve: to operate as a time clock valve, set the
number of days before desired regeneration.
Output Control
Mode
b-01 01 01 or 02
b-01: Signal turns on at start of regeneration and shuts off at
end of regeneration.
b-
02: Signal available in intervals during regeneration cycles and
during In Service.
15