MASTER PROGRAMMING
14
Valve Programming Instructions
When LED is on press and hold both
To program the valve, press
and the
and buttons simultaneously for 3 seconds to unlock.
will turn on. This indicates you are in the programming mode.
To navigate to each programming stage, press
or
To adjust that programming stage value, press
and use the to adjust the values. Follow the steps on next pages.
To exit the programming, press to return to service status.
Programming and Sizing Recommendations
Backwash Time- A normal Backwash is between 10-15 minutes. The higher the turbidity the longer the backwash
time should be set. However, if the turbidity is more than 5FTU it is best to install a pre-filter.
Brine Refill Time -The Brine Refill speed is related to inlet water pressure and brine line flow control.
Fast Rinse Time- Generally Fast Rinse is set for 3-6 times the resin volume; suggest at least 10 minutes.
Regeneration Time- The complete cycle takes about two hours. Set the regeneration time that is convenient for
you. The default setting is 2 AM.
Valve Display
Backwash
Brine & Slow Rinse Brine Refill Fast Rinse
Regeneration Working Process - Service 2 - Backwash 3 - Brine & Slow Rinse 4 - Brine Refill 5 - Fast Rinse
Note: The display screen will display “-00-“when the drive motor is moving from one stage to the next. Each screen
displays for 15 seconds at the start of each stage.